CONSIDER SYSTEM REQUIREMENTS

Consult local building codes and NEC for special instal- lation requirements.

Allow sufficient space for airflow clearance, wiring, refrigerant piping, and unit servicing. See Fig. 2.

Locate unit so that condenser airflow is unrestricted on all sides and above. Refer to Fig. 2.

Unit may be mounted on a level pad directly on base rails or mounted on raised pads at support points. See Table 2 for weight distribution based on recommended support points.

NOTE: If vibration isolators are required for a particular instal- lation, use corner weight information in Table 2 to make proper selection.

Table 2 — Weight Distribution

UNIT

STD UNIT

CORNER

CORNER

CORNER

CORNER

W

 

 

X

 

Y

 

Z

38AK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lb

Kg

Lb

 

Kg

Lb

 

Kg

Lb

 

Kg

Lb

 

Kg

 

 

 

 

 

 

 

 

With Aluminum Coil

 

 

 

 

 

 

007

340

154

86

 

39

53

 

24

77

 

35

124

 

56

008

392

177

86

 

39

78

 

35

99

 

45

107

 

49

012

426

192

89

 

40

92

 

42

109

 

49

105

 

48

S008

510

231

115

 

52

89

 

40

133

 

60

173

 

87

S009,S012

564

256

133

 

60

97

 

44

141

 

64

193

 

88

 

 

 

With Copper Coil

 

 

 

 

 

 

007

386

175

106

 

48

65

 

30

82

 

37

133

 

60

008

460

208

114

 

52

95

 

43

108

 

49

121

 

55

012

503

215

118

 

53

116

 

53

119

 

54

119

 

54

S008

578

262

143

 

65

106

 

48

142

 

64

187

 

85

S009,S012

632

287

161

 

73

114

 

52

150

 

68

207

 

94

NOTES:

1. Dimensions in [ ] are in millimeters.

2. See Fig. 3 for additional information.

Step 2 — Rig and Mount the Unit

Be sure unit panels are securely in place prior to rigging.

RIGGING — These units are designed for overhead rigging. Refer to rigging label for preferred rigging method. Spreader bars are not required if top crating is left on unit. All panels must be in place when rigging. (See Fig. 3.) As further protec- tion for coil faces, plywood sheets may be placed against sides of unit, behind cables. Run cables to a central suspension point so that angle from the horizontal is not less than 45 degrees. Raise and set unit down carefully.

If it is necessary to roll unit into position, mount unit on rails, using a minimum of 3 rollers. Apply force to rails, not unit. If unit is to be skidded into position, place it on a large pad and drag it by the pad. Do not apply any force to unit.

Raise from above to lift unit from rails or pad when unit is in final position.

After unit is in position, remove all shipping materials and top crating.

COMPRESSOR MOUNTING — Compressors are shipped from the factory held down by 4 bolts. After unit is installed, loosen each bolt until the snubber washer can be moved with finger pressure. See Fig. 4.

Step 3 — Complete Refrigerant Piping Con- nections — Suction connection is sweat with plastic cap; liquid connection is sweat with plastic cap. Refer to Table 3A or 3B for the proper line sizes. Follow standard piping practices.

SIZE REFRIGERANT LINES — Consider length of piping required between condensing unit and air handler, amount of liquid lift, and compressor oil return. See Table 4A and 4B and also refer to Part 3 of Carrier System Design Manual for design details and line sizing. Refer to air handler installation instruc- tions for additional information.

Table 3A — Refrigerant Piping Sizes — 60 Hz

LINEAR LENGTH OF PIPING — FT (M)

 

 

0-25

 

25-50

50-75

 

75-100

 

UNIT

(0-7.6)

 

(7.6-15.2)

(15.2-22.9)

(22.9-30.5)

38

 

 

 

 

Line Size (in. OD)

 

 

 

 

 

L

S

 

L

S

L

S

 

L

S

 

AK007

1/

11/

8

1/

11/

1/

11/

8

1/

11/

8

 

 

2

 

2

8

2

 

2

 

AK008

1/

2

11/

8

1/

11/

5/

11/

8

5/

13/

8

 

 

 

2

8

8

 

8

 

AK012

5/

11/

8

5/

13/

5/

13/

8

5/

13/

8

 

 

8

 

8

8

8

 

8

 

AKS008

1/

11/

8

1/

11/

5/

11/

8

5/

13/

8

 

 

2

 

2

8

8

 

8

 

AKS009

5/

11/

8

5/

11/

5/

13/

8

5/

13/

8

 

 

8

 

8

8

8

 

8

 

AKS012

5/

11/

8

5/

11/

5/

13/

8

5/

13/

8

 

 

8

 

8

8

8

 

8

 

LEGEND

LLiquid LIne S — Suction Line

Table 3B — Refrigerant Piping Sizes — 50 Hz

LINEAR LENGTH OF PIPING — FT (M)

 

0-25

25-50

50-75

75-100

UNIT

(0-7.6)

(7.6-15.2)

(15.2-22.9)

(22.9-30.5)

38

 

 

Line Size (in. OD)

 

 

 

L

S

L

S

L

S

L

S

AK007

1/2

11/8

1/2

11/8

1/2

11/8

1/2

11/8

AK008

1/2

11/8

1/2

11/8

5/8

13/8

5/8

13/8

AK012

5/8

11/8

5/8

13/8

5/8

13/8

5/8

13/8

AKS008

1/2

11/8

1/2

11/8

5/8

13/8

5/8

13/8

AKS009

5/8

11/8

5/8

11/8

5/8

13/8

5/8

13/8

AKS012

5/8

11/8

5/8

11/8

5/8

13/8

5/8

13/8

LEGEND

LLiquid LIne S — Suction Line

NOTES FOR TABLES 3A AND 3B:

1.Pipe sizes are based on a 2 F (1 C) loss for liquid and suction lines.

2.Pipe sizes are based on the maximum linear length shown for each column, plus a 50% allowance for fittings.

3.Charge units with R-22 in accordance with unit installation instructions.

4.Line size conversion to mm is:

in. mm

1/2 12.7

5/8 15.9

11/8 28.6

13/8 34.9

4

Page 4
Image 4
Carrier 38AK008 Rig and Mount the Unit, Weight Distribution, Refrigerant Piping Sizes 60 Hz, Linear Length of Piping FT M

38AK012, 38AKS009, 38AKS012, 38AKS008, 38AK008 specifications

The Carrier 38AK007 is a state-of-the-art air conditioning system designed for optimal comfort, efficiency, and reliability, making it a standout choice for residential and commercial applications. This model exemplifies Carrier's commitment to innovation and energy efficiency, catering to diverse cooling needs.

One of the key features of the Carrier 38AK007 is its high energy efficiency ratio (EER), which ensures lower energy consumption and reduced utility bills. With advanced inverter technology, this unit adjusts its cooling output based on the current requirements, thereby minimizing energy waste. This makes it an environmentally friendly option, contributing to lower greenhouse gas emissions while providing effective cooling.

The Carrier 38AK007 is also equipped with a variable-speed compressor, which enhances its performance and reliability. The compressor operates at different speeds, allowing the system to maintain a consistent room temperature without the peaks and valleys associated with traditional systems. This ensures not only increased comfort but also quieter operation, making it ideal for homes, offices, and other noise-sensitive environments.

In terms of technological innovation, the Carrier 38AK007 features Smart Thermostat compatibility, allowing users to control their cooling settings remotely via a smartphone or tablet. This integration with smart home systems provides users with added convenience, enabling them to adjust temperature settings from anywhere, ensuring optimal comfort even before arriving home.

The model is built with a robust and durable construction, featuring weather-resistant materials that withstand various environmental conditions. This durability ensures a long lifespan, reducing the frequency and costs of maintenance. Additionally, the Carrier 38AK007 includes a multi-stage filtration system that effectively captures allergens and pollutants from the indoor air, improving overall air quality.

Overall, the Carrier 38AK007 is designed to meet the modern demands for energy efficiency, user control, and durability. Its combination of advanced technologies, such as inverter technology and smart home compatibility, along with high performance and air quality features, makes it an excellent choice for anyone looking to invest in a reliable cooling solution. Whether for a residential setting or a commercial space, the Carrier 38AK007 stands out as a leader in the air conditioning market.