| 48SS018, 024, 030, 036, 042, 048 & 060 |
|
|
Date: | Supersedes: | 48SS | Rev.: | |
|
| COMBINATION GAS HEATING/ | ||
|
|
| ||
|
| ELECTRIC COOLING UNITS |
|
|
|
|
|
|
|
JOB DATA: | LOCATION: |
|
| |
|
|
|
|
|
BUYER: |
| BUYER P.O. # | CARRIER # |
|
|
|
|
|
|
UNIT NUMBER: | MODEL NUMBER: |
|
| |
|
|
|
|
|
PERFORMANCE DATA CERTIFIED BY: |
| DATE: |
| |
|
| DESCRIPTION |
|
|
|
| 48SS units are | ||
|
|
|
| |
|
| 48SS units are convertible discharge units that can be used for either horizon- | ||
|
| tal or down discharge installations. |
|
|
ARI 210 | ARI 270 |
|
|
|
FEATURES
Standard
Units are ``Rated in accordance with ARI Standard No. 270 and 210/240.''
Standard unit as factory assembled is design certi®ed and listed by UL and CSA.
Low temperature cooling operation standard to 40 F (4 C).
Hermetic compressor with internal linebreak and overload protec- tion, self lubricating. Scroll compressors on 4 and 5 ton sizes.
Crankcase heater is standard on
Indoor and outdoor coils constructed of aluminum ®ns mechan- ically bonded to seamless copper tubes.
48SS units have
Sloped
Alternate electrical connections on opposite sides of unit.
Disconnect in accordance with NEC, must be
Weatherized cabinets. Heavy duty phosphated
Heating controls include a direct spark ignition with ¯ame recti®cation. Fan switch, overtemperature switch, and ¯ame roll- out switch also included.
Alumaguard™ coated
Integrated gas control board provides
Base rail standard on all
PERFORMANCE DATA
Operating Weight |
| lb (unit); |
|
|
| lb (curb) | CFM |
| Ext. Static Pressure |
|
|
|
| in. wg | |||||||||||||||||
COOLING |
|
|
|
|
|
|
|
|
|
| Indoor Fan Motor |
|
| Hp |
|
| Rpm |
|
|
| Bhp | ||||||||||
Net Total Capacity |
|
|
|
|
|
|
| Btuh | HEATING |
|
|
|
|
|
|
|
|
|
| ||||||||||||
Net Sensible Capacity |
|
|
|
|
|
|
| Btuh |
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
| Input |
|
|
|
|
|
|
|
| Btuh | ||||||||||||||||
Compressor Power Input |
| kW | @ |
|
|
|
|
| °F |
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| Output |
|
|
|
|
|
|
|
|
| Btuh | ||||||||||
Indoor Entering Air db |
|
| °F | wb |
|
|
|
| °F |
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
| AFUE |
|
|
| % |
|
|
|
| |||||||||||||||||||
SEER/EER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRICAL DATA
Power Supply to Unit |
| Volts |
| Phase |
| Hz. | |||
Minimum Circuit Amps |
|
| Maximum Overcurrent Protection |
|
|
ACCESSORIES AND OPTIONS
Commercial Grade Base Rail
Dedicated Downshot/Base Rail
FIELD-INSTALLED ACCESSORIES
30% Open Manual Fresh Air Damper Roof Curb:
8Height
11Height
14Height
Crankcase Heater Ð Single Phase Only (Required with 0° Low Ambient)
FIELD-INSTALLED ACCESSORIES (cont)
Programmable Electronic Thermostat Thermostat and Subbase
0° Low Ambient
Time Guard II L.P. Conversion Kit
Controls Upgrade Kit (High and
External Condensate Trap
Natural Gas
2