Carrier SYSTXCC4ZC01 instruction manual Table of Contents, Safety Considerations, Introduction

Models: SYSTXCC4ZC01

1 8
Download 8 pages 5.75 Kb
Page 1
Image 1

SYSTXCC4ZC01

Infinity Damper Control

Visit www.carrier.com

Installation and Start-Up Instructions

Infinity Damper Control

SYSTXCC4ZC01

A97040

NOTE: Read the entire instruction manual before starting the

installation.

 

This symbol indicates a change since the last issue.

 

TABLE OF CONTENTS

 

SAFETY CONSIDERATIONS

1

INSTALLATION CONSIDERATIONS

1

INTRODUCTION

1

INSTALLATION

2

Check Equipment and Job Site

2

Component Location and Wiring Considerations

2

Install Components

3

Install Zone Dampers

3

Final Wiring

4

Additional Damper Control Board Setup

5

Optional Transformer Requirements

5

System Startup

5

TROUBLESHOOTING

7

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause fire, electrical shock, or other conditions that may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for infor- mation or assistance. The qualified installer or agency must use factory authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes and wear safety glasses. Have fire extinguisher available. Read these in- structions thoroughly and follow all warnings or cautions attached to the unit. Consult local and state building codes and Sheet Metal and Air Conditioning National Association (SMACNA) for special installation requirements.

This is the safety-alert symbol . When you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury. Understand the signal words DAN-

GER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards, which will result in severe personal injury or death. WARNING signifies a hazard, which could result in personal injury or death. CAUTION is used to identify unsafe practices, which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

INSTALLATION CONSIDERATIONS

Before the actual installation of a zoning system can begin, decisions need to be made to determine the number and location of zones and sensors. This affects duct and damper selections.

This instruction covers the physical installation and start up of the Infinity Damper Control. Use this instruction to guide the actual installation process after all the air side decisions have been made. One Damper Control is capable of handling up to four zones of operation. When greater than four zones are required, a second Damper Control Module is needed for zones 5 through 8 (8 zones maximum).

1.Install the Infinity Zone Control (User Interface) and Remote Room Sensors in non-condensing areas with ambient tempera- tures between 32° F. and 120° F. Install Dampers and Infinity Damper Control in non-condensing areas with ambient tem- peratures between -4° F. to 158° F., (-20° to 70° C).

2.A TXV is required on the indoor coil when used with all residential split system equipment.

3.Proper equipment selection and duct sizing are important in a zoned system.

4.DO NOT USE a bypass damper with the Infinity Zoning System. Addition of a bypass will cause improper operation. Airflow management will be performed by the User Interface algorithms. The User Interface will monitor the system and will maintain proper airflow through the heating / cooling equipment.

INTRODUCTION

The Infinity Zoning System allows air conditioning and heating equipment to control temperatures and humidity in up to 8 distinct spaces, or zones, within a building. Each zone has independent temperature settings. The comfort temperature settings can change automatically through the use of schedules. This allows the Infinity System to change temperature settings in zones to reflect occu- pancy or usage. For example, the end user can condition bedrooms in a home from 5:00 PM through 7:00 AM or the kitchen from 3:00 PM through 6:00 PM. The Infinity System uses motorized air volume control dampers (also called zone dampers) to regulate flow of conditioned air into zones. In this manner, the system can selectively heat or cool certain portions of a building depending upon space temperature requirements.

Each zone requires a motorized zone damper to control the air supplied to it and a zone sensor to sense temperature in each zone. There are three types of zone sensors available and may be used in combination:

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book

1

4

PC 101

Catalog No. 809-50012

Printed in U.S.A.

Form DAMP4ZC-1SI

Pg 1

04-04

Replaces: NEW

Tab

misc.

misc.

 

 

 

 

 

 

Page 1
Image 1
Carrier SYSTXCC4ZC01 instruction manual Table of Contents, Safety Considerations, Installation Considerations

SYSTXCC4ZC01 specifications

The Carrier SYSTXCC4ZC01 is an advanced thermostat designed to enhance the comfort and efficiency of residential heating and cooling systems. This device offers a blend of cutting-edge technology and user-friendly features, making it an ideal choice for homeowners looking to optimize their indoor climate.

One of the standout features of the SYSTXCC4ZC01 is its Wi-Fi connectivity. This allows users to control their HVAC systems remotely through a smartphone app, providing convenience and flexibility. Whether you’re at home, work, or on vacation, you can adjust the temperature, set schedules, and monitor energy consumption in real-time from virtually anywhere. This remote access not only enhances comfort but also supports energy savings by allowing homeowners to manage their heating and cooling efficiently.

The thermostat also boasts a sleek, modern design with a colorful touchscreen display. The intuitive interface makes it easy to navigate and customize settings. Furthermore, the SYSTXCC4ZC01 is equipped with advanced diagnostics capabilities. This feature not only helps in troubleshooting any potential issues but also assists homeowners in maintaining their systems more effectively, promoting longevity and reducing maintenance costs.

In terms of technology, the Carrier SYSTXCC4ZC01 is compatible with various heating and cooling systems, including single-stage and multi-stage setups. It supports heat pumps, gas furnaces, and air conditioning systems, offering versatility to meet different homeowner needs. The thermostat’s ability to handle multiple zones also allows for precise temperature control in larger homes, ensuring that each room maintains its desired level of comfort.

Energy efficiency is a core focus of the SYSTXCC4ZC01. The thermostat is designed to work in conjunction with Carrier’s Infinity system, integrating seamlessly to optimize performance and reduce energy costs. By using advanced algorithms, the thermostat learns the homeowner's preferences and schedules to minimize energy use without sacrificing comfort.

Additionally, the SYSTXCC4ZC01 includes smart alerts that notify users of filter changes, system maintenance, and extreme temperature fluctuations. This proactive feature empowers homeowners to make informed decisions about their HVAC systems, leading to increased efficiency and cost savings over time.

In summary, the Carrier SYSTXCC4ZC01 thermostat is a comprehensive solution for modern home climate control. With its Wi-Fi connectivity, intuitive interface, advanced diagnostics, compatibility with various systems, and focus on energy efficiency, it stands out as a leader in home comfort technology.