Carrier SYSTXCC4ZC01 instruction manual Damper 24-vac Connections, Final Wiring

Models: SYSTXCC4ZC01

1 8
Download 8 pages 5.75 Kb
Page 4
Image 4

SET SCREW

SET SCREW

MOUNTING HUB

 

3/16"

 

 

GAP

 

 

MOUNTING HUB

 

 

ACTUATOR

HOUSING

DAMPER

 

PLASTIC COVER

 

 

 

QUICK BLADE

 

 

 

RELEASE

 

 

 

CLS

COM OPN

 

 

CLS

COM

 

 

 

OPN

3/16"

 

(CLS) CLOSED

 

 

(COM) COMMON

 

GAP

ANTI-ROTATION

ANTI-ROTATION

(OPN) OPEN

 

MOUNTING SCREW

MOUNTING SCREW (5/16")

 

 

Fig. 1 — Damper 24-vac Connections

C03024

1/2 STEEL STRAP

Fig. 2 — Insulated Round Metal Duct Work

A95130

S-LOCK

SUPPLY

AIR DUCT

DRIVE ZONE

DAMPER

Fig. 3 — Rectangular Metal Duct Work

A92478

1 1/2 " TO 2"

INSULATION

Fig. 4 — Insulated Rectangular Metal Duct Work

A95131

Step 5—FINAL WIRING

Bring all damper and sensor wires together at the Infinity Damper Control. Make all system wiring connections as indicated in Fig. 9. The two ABCD bus connections on the Infinity Damper Control

FLEXIBLE

ZONE

DUCT

DAMPER

Fig. 5 — Round Flexible Duct Work

A95132

1/2 STEEL STRAP

Fig. 6 — Insulated Round Flexible Duct Work

 

A95133

FIBROUS

FIELD

GLASS

SUPPLIED

DUCTWORK

SCREWS

 

 

ZONE

 

DAMPER

2TO 3

Fig. 7 — Rectangular Fibrous Glass Duct Work

A92480

1 1/2 TO 2

INSULATION

Fig. 8 — Insulated Rectangular Fibrous Glass Duct

Work

A95134

are in parallel with each other. Use either terminal block to connect the Zoning User Interface, Smart Sensor(s), variable-speed indoor unit and 2-speed communicating outdoor unit (if applied). If more than four zones are required (up to 8 zones maximum), see Step—6 and Fig. 10 for Additional Damper Control Board Setup for Zones 5-8.

VENTILATOR WIRING — The Infinity Damper Control can control a Carrier Heat Recovery Ventilator or Energy Recovery Ventilator (HRV / ERV). Connect the four wires from the ventilator control board (see ventilator installation instructions for details) to the connector labeled (YRGB). This label identifies the color of the wire to match the ventilator wire colors (Y=yellow, R=red, G=green, B=blue or black). If you have two Infinity Damper Controls, connect the ventilator to the control for zones 1 through 4.

LEAVING AIR TEMPERATURE / HEAT PUMP TEM- PERATURE (LAT/HPT) SENSORS — These inputs on the

Infinity Damper Control are used only for diagnostic purposes and

4