| | | ACCESSORIES |
| | | | |
| ACCESSORY | FORM NUMBER | PART NUMBER | DESCRIPTION |
| Wall Sleeves | 52S-48SI | WALL-SLEEVE-1PK | Non-Insulated Plastic Wall Sleeve, 1 per pack |
| | | WALL-SLEEVE-9PK | Non-Insulated Plastic Wall Sleeve, 9 per pack |
| | | SLEEVE-INSUL-1PK | Insulated Plastic Wall Sleeve, 1 per pack |
| | 52S-50SI | SLEEVE-STEEL-1PK | Insulated Metal Wall Sleeve, 1 per pack |
| | 52S-49SI* | SLEEVE-EXT24-1PK | Extended Metal Wall Sleeve for Deep Wall Applications (24 in. deep), 1 per pack |
| Exterior Grilles† | 52S-59SI | GRILLE-ALU-STAMP | Stamped Aluminum Exterior Grille, Clear Finish |
| | 52S-58SI | GRILLE-PLA-BROWN | Plastic Architectural Rear Grille, Brown |
| | | GRILLE-PLA-BEIGE | Plastic Architectural Rear Grille, Beige |
| | 52S-60SI | GRILLE-ALU-CLEAR | Aluminum Architectural Exterior Grille, Clear Finish |
| | | GRILLE-ALU-WHITE | Aluminum Architectural Exterior Grille, White |
| | | GRILLE-ALU-BRONZ | Aluminum Architectural Exterior Grille, Light Bronze |
| | | GRILLE-ALU-MBRNZ | Aluminum Architectural Exterior Grille, Medium Bronze |
| | | GRILLE-ALU-BROWN | Aluminum Architectural Exterior Grille, Brown (Dark Bronze) |
| | | GRILLE-ALU-BEIGE | Aluminum Architectural Exterior Grille, Beige |
| | | GRILLE-ALU-ALPIN | Aluminum Architectural Exterior Grille, Alpine (matches Carrier Wall Sleeve) |
| | | GRILLE-ALU-PEACH | Aluminum Architectural Exterior Grille, Peach |
| | | GRILLE-ALU-MELON | Aluminum Architectural Exterior Grille, Melon |
| | | GRILLE-ALU-LGREY | Aluminum Architectural Exterior Grille, Light Grey |
| | | GRILLE-ALU-SGREY | Aluminum Architectural Exterior Grille, Slate Gray |
| | | GRILLE-ALU-RDBRK | Aluminum Architectural Exterior Grille, Red Brick |
| | | GRILLE-ALU-BLUE | Aluminum Architectural Exterior Grille, Blue |
| | | GRILLE-ALU-GREEN | Aluminum Architectural Exterior Grille, Green |
| Subbase | 52C,P-1SI | SUBBASE-NON-ELEC | Non-electrical Subbase |
| | 52C,P-2SI | SUBBASE-230V-15A | Electrical subbase with factory-installed 208/230V, 15 amp receptacle |
| | | SUBBASE-230V-20A | Electrical subbase with factory-installed 208/230V, 20 amp receptacle |
| | | SUBBASE-230V-30A | Electrical subbase with factory-installed 208/230V, 30 amp receptacle |
| | | SUBBASE-265V-15A | Electrical subbase with factory-installed 265V, 15 amp receptacle |
| | | SUBBASE-265V-20A | Electrical subbase with factory-installed 265V, 20 amp receptacle |
| | | SUBBASE-265V-30A | Electrical subbase with factory-installed 265V, 30 amp receptacle |
| | 52C,P-3SI | SUBBASE-HARDWIRE | Electrical subbase with factory-installed hardwire kit (230/208V and 265V) |
| Subbase | 52C,P-8SI | SUBBASE-HW-KIT | Subbase Hardwire Kit, to make a non-electrical subbase, hardwired in the field |
| Field-Installed | | | (230/208V and 265V) |
| Kits | | | |
| 52C,P-6SI | RECEPT-230V-15A | Subbase 208/230V, 15 amp Receptacle Kit, to add a receptacle to a non-electrical |
| |
| | | | subbase in the field |
| | | RECEPT-230V-20A | Subbase 208/230V, 20 amp Receptacle Kit, to add a receptacle to a non-electrical |
| | | | subbase in the field |
| | | RECEPT-230V-30A | Subbase 208/230V, 30 amp Receptacle Kit, to add a receptacle to a non-electrical |
| | | | subbase in the field |
| | | RECEPT-265V-15A | Subbase 265V, 15 amp Receptacle Kit, to add a receptacle to a non-electrical |
| | | | subbase in the field |
| | | RECEPT-265V-20A | Subbase 265V, 20 amp Receptacle Kit, to add a receptacle to a non-electrical |
| | | | subbase in the field |
| | | RECEPT-265V-30A | Subbase 265V, 30 amp Receptacle Kit, to add a receptacle to a non-electrical |
| | | | subbase in the field |
| | 52C,P-4SI | SUBBASE-SWITCH | Field-Installable Switch kit for an electrical subbase |
| | 52C,P-5SI | SUBBASE-FUSE-15A | Field-Installed Fuse Kit (15 amp) for electrical subbase |
| | | SUBBASE-FUSE-20A | Field-Installed Fuse Kit (20 amp) for electrical subbase |
| | | SUBBASE-FUSE-30A | Field-Installed Fuse Kit (30 amp) for electrical subbase |
| Electrical | 52C,P-11SI | HARDWIRE-KIT-1PK | Permanent power connection to the unit (includes 36" of flexible conduit and unit-mounted |
| Connections | | | connector, 230/208V and 265V) 1 per pack |
| Condensate | 52S-53SI | DRAIN-KIT-4PK | Attaches to wall sleeve for controlled internal or external disposal of condensate 4 per pack |
| Drain Kit | | | |
| Wall | N/A | HH01AD045 | Electro-mechanical Wall Thermostat (Heat/Cool and Heat Pump) |
| Thermostats | | TSTATCCBPC01-B | Value Series Electronic Thermostat w/Digital display (Heat/Cool Models) |
| | | TSTATCCBPH01-B | Value Series Electronic Thermostat w/Digital display (Heat Pump Models) |
| | | TSTATCCPAC01-B | 7-Day Programmable Electronic Thermostat (Heat/Cool Models) |
| | | TSTATCCPHP01-B | 7-Day Programmable Electronic Thermostat (Heat Pump Models) |
| Wall Thermostat | 52C,P-7SI | RC-FIELDKIT230HC | Field-installed wall thermostat retrofit kit to convert a standard 230V Heat/Cool unit to an |
| Interface | | | RC unit. Wall thermostat sold separately. |
| Retrofit Kit | | RC-FIELDKIT230HP | Field-installed wall thermostat retrofit kit to convert a standard 230V Heat Pump unit to an |
| | | | RC unit. Wall thermostat sold separately. |
| | | RC-FIELDKIT265HC | Field-installed wall thermostat retrofit kit to convert a standard 265V Heat/Cool unit to an |
| | | | RC unit. Wall thermostat sold separately. |
| | | RC-FIELDKIT265HP | Field-installed wall thermostat retrofit kit to convert a standard 265V Heat Pump unit to a |
| | | | RC unit. Wall thermostat sold separately. |
| Replacement | N/A | AIR-FILTER-10PK | Replacement air filters in package of 10 |
| Filters | | | |
| Energy | 52C,P-10SI | EM-KIT | Allows unit to be turned on and off from a remote location (includes freeze guard |
| Management | | | protection) |
| Locking Security | 52C,P-13SI | SECURITY-DOOR | Key-locking security door to prevent access to heating and cooling controls |
| Control Door | | | |
| Lateral Duct Kit | 52C,P-14SI | LATERAL-DUCT | Ductwork to allow one unit to heat and cool two rooms (plenum plus extension duct and registers) |
| Air Deflector | 52C,P-9SI | DEFLECTOR-1PK | Lateral air deflector, with individually adjustable louvers, to enhance air circulation, 1 per pack |