Carrier Access 52C Operation, Comfort Controls, ADJUST AIRFLOW DIRECTION - The discharge

Models: 52C

1 16
Download 16 pages 37.89 Kb
Page 8
Image 8
OPERATION

52C

SERIES

OPERATION

COMFORT CONTROLS

ADJUST AIRFLOW DIRECTION — The discharge

air grille is mounted on the front panel so that the air

discharges forward. If upward discharge is required,

remove the grille by removing screws on back of front

panel. Rotate grille 180 degrees and reinstall on the

front panel.

ADJUST VENT — The vent handle is on the left

side of the unit. Turn handle to open or close vent.

Vent will remain in last desired position until handle

 

75

80

70

 

8565

90 COMFORT CONTROLS 60

TEMPERATURE

CONTROL

STANDOFF

PINS

CON

is turned again. Magnet will ensure positive closure.

See Figure 13.

SETTING TEMPERATURE LIMITS — Setting tem-

perature limits on the unit provides the user a

restricted range of temperature control. See Figure 14.

NOTE: This adjustment is optional and is not appli- cable to remote control units.

The temperature limits are factory set to full range, which is 60 F to 90 F. To set restricted rotation of the temperature control knob:

1.Remove front panel.

2.Remove temperature control knob to expose tem- perature limiter.

3.Remove standoff pins from the 60 F and 90 F indi- cator holes.

4.Replace standoff pin in hole for desired minimum temperature.

5.Replace standoff pin in hole for desired maximum temperature.

6.Reinstall temperature control knob.

7.Reinstall front panel.

NOTE: Temperature indicators stamped on tem- perature limiter are approximate and represent degrees F.

FAN CYCLE SWITCH

CYC

OUTDOOR THERMOSTAT (HEAT PUMP UNITS ONLY)

VENT HANDLE

MAGNET

CLOSE

OP

EN

 

VENT VENT

DOOR FILTER

FIGURE 13 — 52C VENT DOOR

FIGURE 14 — 52C OPERATING CONTROLS

8

Page 8
Image 8
Carrier Access Operation, Comfort Controls, ADJUST AIRFLOW DIRECTION - The discharge, 52C VENT DOOR, 52C SERIES