ELECTRICAL DATA
ELECTRICAL SHOCK HAZARD
DO NOT alter cord or plug, and DO NOT use an extension cord. Personal injury or damage to the unit may result.
Be sure that your outlet matches the appropriate blade configuration of the supplied plug and that it is within reach of the service cord. A hardwire kit is available as an accessory to change
IMPORTANT: All standard
ALL UNITS
■WIRE SIZE — Use recommended wire size given in Table 1 and install a single branch circuit. All wiring must comply with local and national codes. All units are designed to operate off single branch cir- cuits only.
NOTE: Use copper conductors only.
■GROUNDING — For safety and protection, the unit is grounded through the service cord plug or through separate ground wire provided on hardwired units. Be sure that the branch circuit or general purpose outlet is grounded.
TABLE 1 — SUGGESTED BRANCH CIRCUIT
WIRE SIZES*
NAMEPLATE AMPS | AWG WIRE SIZE† |
7.0 to 12 | 14 |
12.1 to 16 | 12 |
16.1 to 24 | 10 |
LEGEND
AWG — American Wire Gage
*Single circuit from main box.
†Based on copper wire at 60 C temperature rating.
VOLTAGE SUPPLY
Check voltage supply at outlet. For satisfactory re- sults, the voltage range must always be within the ranges found on the data information plate (Figure 1).
■
TABLE 2 — RECEPTACLES AND FUSE TYPES — 250,265 VOLTS
RECEPTACLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 15 Amps | 20 Amps | 30 Amps | 15 Amps | 20 Amps | 30 Amps | ||||||||||||||||||||||||||
RATED VOLTS | 250 |
| 250 |
| 250 |
| 265 | 265 | 265 |
| ||||||||||||||||||||||
15 |
| 20* |
| 30 |
| 15 | 20 | 30 |
|
| ||||||||||||||||||||||
FUSE (or HACR Circuit Breaker) |
|
|
|
|
| |||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
LEGEND |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HACR — Heating, Air Conditioning, Refrigeration |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
*May be used for |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4