Carson SC-407 Light Control Rocker Switch Connections, Switch Lead Sets, Load C Load D, Load A

Models: SC-407

1 12
Download 12 pages 3.57 Kb
Page 7
Image 7
Light Control Rocker Switch Connections

SC-407-10 Ver. B Installation and Operating Instructions

Page 7 of 12

Light Control Rocker Switch Connections

The following diagram shows proper connection of the rocker switch leads located at the rear.

Note: Negative (NEG) connection must also be made on 10-Pin plug for rocker switches to light up.

WARNING: The lighting control circuits of this unit are not fused. Automotive fuses or circuit breakers must be connected between the power source and the unit properly rated for the circuit requirements. Failure to install proper circuit breakers or fuses can result in damage to the unit and/or vehicle.

A B C D

LOAD C

LOAD C LOAD D

 

GRN

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

 

 

LOAD A

 

 

BLU

 

RED YEL

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOAD B

 

 

 

 

 

 

RED YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D C B A

Circuit Breakers

+

Recommended

Wire Size

Amps Size

5 - 10 #16

10 - 15 #14

15 - 30 #12

30 - 40 #10

40 - 50 #8

50 - 60 #6

Use next larger size if longer than 10 ft.

or Fuses BATT

20 AMP Max. LOAD A -

Switch Lead Sets

Switch Leads Hole

AGRN/YEL Center

B BLU/RED Center

C GRN/YEL Left

D BLU/RED Left

CP4842C

05/07/05

Page 7
Image 7
Carson SC-407 Light Control Rocker Switch Connections, Switch Lead Sets, Load C Load D, Load A, Load B, D C B A