Carson SC-407 Light Control Connections, Fuses / Breakers, Lever Switch Connections

Models: SC-407

1 12
Download 12 pages 3.57 Kb
Page 6
Image 6
LIGHT CONTROL CONNECTIONS

Page 6 of 12

SC-407-10 Ver. B Installation and Operating Instructions

LIGHT CONTROL CONNECTIONS

In addition to these instructions a label located on the bottom of the unit shows the light control switch connections.

Fuses / Breakers

The lighting control circuits of this unit are not fused. Automotive fuses or circuit breakers must be connected between the power source and the unit properly rated for the circuit requirements.

Failure to install proper circuit breakers or fuses can result in damage to the unit and/or vehicle.

Lever Switch Connections

The following diagram shows proper connection of the lever switch leads located at the rear. Note: Negative (NEG) connection must also be made on 10-Pin plug for proper operation.

Recommended

Wire Size

LOAD 1

LOAD 2

LOAD 3

YEL

GRN

BLU

RED

Circuit Breaker

or Fuse

60 AMP Max.

Fuses / BreakersLever Switch Connections +

BATT

-

Amps Size

5 - 10 #16

10 - 15 #14

15 - 25 #12

25 - 40 #10

40 - 60 #8

60 - 80 #6

Use next larger size if longer than 10 ft.

Off 1 2 3

Lever

Turns

Position

On

Off

All off

1Load 1 only

2 Loads 1 and 2

3 Loads 1, 2 and 3

05/07/05

CP4842C

Page 6
Image 6
Carson SC-407 Light Control Connections, Fuses / Breakers, Lever Switch Connections, Circuit Breaker or Fuse 60 AMP Max