Horn Ring Cycler 2 (Optional)

SC-407-10 Ver. B Installation and Operating Instructions

Page 9 of 12

Horn Ring Cycler 2 (Optional)

During installation, the auxiliary input may be connected to the horn ring or other switching device, and the HRC2 option programmed. With the Selector Switch set to the STBY position, tap the horn ring to bring the unit out of standby into Wail tone. Repeatedly tapping the horn ring will cycle through Wail, Yelp, and Phaser tones. Tapping the horn ring twice quickly will stop the siren tones and return the unit to standby. Pressing and holding the horn ring will produce Horn tone until released. Then the siren will return to its previous siren tone or standby. Please note that this option disables Phaser selection in the Wail or Yelp selector switch positions.

NOTE: Earlier models with S/N lower than 04190000 have a different version of HRC. In this case the siren tones cycle through Standby, Wail, Yelp, and Phaser. The tone is stopped by cy- cling to Standby.

LIGHT SYSTEM CONTROLS

This unit provides large, durable switches for light control function. A 4-position lever switch pro- vides control of primary lighting functions. It also provides automatic activation of the siren sys- tem.

Setting the siren control switch to the On position can turn on backlighting of the light control switches.

Lever Switch

 

 

 

 

 

 

The lever switch provides additive control of lighting functions.

 

 

 

 

 

 

Position 1 turns on a single lighting function, such as lights

OFF

 

1

2

3

pointing to the rear. Position 2 turns on an additional light func-

 

 

 

 

 

 

 

tion, such as lights pointing to the front. Position 3 turns on an

 

 

 

 

 

 

 

 

 

 

 

 

additional 3rd lighting function, such as strobes. Position 3 also

 

 

 

 

 

 

turns on a siren function (see below). The installer determines

 

 

 

 

 

 

actual function.

 

 

 

 

 

 

Common wiring configures the lever switch to operate as position 1 = parked, 2 = takedown and 3 = pursuit modes.

Automatic Siren

Position 3 of the lever switch provides automatic siren control. With both siren control rocker switches set at center position (Stby/Off) the unit will activate the Wail siren tone. With the siren control switches set at Yelp/Off position 3 will activate the Yelp siren tone. The Man/Phsr and Horn switches will operate as if the siren control switches were set at the corresponding positions. PA override is also functional. Automatic siren operation will not work if the right siren control switch is set in the Rad position or the installer has disabled the function.

Rocker Switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Four rocker switches are provided for vari-

 

L ALY

 

 

R ALY

 

 

AUX 1

 

 

AUX 2

ous other lighting functions, such as alley

 

 

 

 

 

 

 

lights, deck lights, headlight flashers, etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The switches light when turned on for night

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

use.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 