SC-411RD-10

Installation and Operating Instructions

Page 9 of 12

OFF 12

S1

 

S2

 

 

 

 

YELP

PHSR CARSON

 

WAIL

CYCLE

 

3

STBY

RADIO

 

 

 

 

HORN

MANUAL

PA VOL

 

OUT/DIM

 

SC-411

 

 

Elite Force

S3

 

S4

 

S5

 

S6

 

 

 

 

 

 

 

WARNING: WEAR HEARING PROTECTION REF. OSHA 1910.95

LIGHT SYSTEM CONTROLS

A 4-position lever switch provides control of primary lighting functions. It also provides automatic activation of the siren. Six additional programmable pushbuttons provided for auxiliary lighting or other device control. Two dedicated switches operate directional control lights (“Arrow Stick”), with flashing indicators on the control panel.

Lever Switch - The lever switch by default provides progressive (additive) control of lighting functions. The third position also provides Automatic Siren. The installer can change to non-progressive operation.

Automatic Siren - Position 3 of the lever switch provides Automatic Siren control. If the siren controls are set where there is no siren tone output, the Automatic Siren will override with Wail or other tone. The cutout input will stop the siren tone. This feature may be disabled.

Auxiliary Control Switches - Six lighted pushbutton switches are provided for various other lighting functions or device control. The switch lights Red when activated. The switches may also be programmed for different functions, and these switches may be combined with each lever switch position to automatically turn on and off.

Arrow Stick Control Switches - Two dedicated switches are provided to control traffic director lights on the vehicle. Press left or right buttons to set the direction. Turning on both will set the output to left, right and cen- ter. Lights show the operation selected.

Switch Legends - Different legends may be selected to match the device controlled. A sheet of labels is sup- plied.

OUT/DIM - The backlighting and indicator lights can be dimmed or turned off by repeatedly pressing the OUT/ DIM button. An optional connection to the vehicle dash lights may also control this level. This button will light whenever a siren tone is produced.

Video Trigger Output - A video camera trigger output is activated with the lever switch in position 1, 2, or 3. Programmed auxiliary control switches may also activate the output.

Alert - While the lever switch or auxiliary control switches are on, an alert beep is sounded every 15 seconds. This can be optionally disable.

DIAGNOSTICS

The unit monitors all outputs for faults, which are usually traced to shorted circuits. The unit indicates these faults by flashing one or more lights and beeping. The following table shows fault indications and likely causes.

Control

Fault Indication

Likely Cause

 

 

 

Lever Switch light 1, 2 or 3

1, 2 or 3 flashes

Blown fuse at 1, 2 or 3

 

 

 

Switch 1 - Switch 6

Switch light flashes

Blown fuse at S1 - S6

 

 

 

Arrow Stick Switch

Switch light flashes

LFT-A, RGT-A or CTR-A output shorted (auto-reset)

 

 

 

Siren output 1

OUT/DIM light flashes

Blown fuse at siren CH1

 

 

 

Siren output 2

OUT/DIM light double

Blown fuse at siren CH2

flashes

 

 

Both siren outputs

OUT/DIM light triple

Blown fuses at siren CH1 & CH2

flashes

 

 

PROGRAM TRANSFER (QuickClone™)

 

To facilitate programming of multiple vehicles this unit automatically synchronizes option settings between the

control head and amplifier on power-up as shown. Transfer the settings to multiple vehicles by temporarily installing with a com- mon control head, power-up/down (transferring options to the amplifier), then permanently install the supplied control head. On power-up the options are transferred from the amplifier to the control head.

If a control head or amplifier is sent in for service it will be set to default prior to return, and will automatically synchronize with the mating part on power-up.

Option Settings

Action

 

 

Head = Amp

Normal power-up

 

 

Head Default and

Head transferred to

Amp Default

Amp, power-up

Amp = Default and

Head transferred to

Head Default

Amp, power-up

Amp Default and

Amp transferred to

Head = Default

Head, power-up

CP5094C

7/30/12

Page 9
Image 9
Carson SC-411-RD-1014 Light System Controls, Diagnostics, Control Fault Indication Likely Cause, Option Settings Action