7
R
R

Thewallcontrolinstallsinthesamemannerasanordinarylightswitch,using anexistingjunctionboxandwiring.This

controller is designed to signal the fan microcomputer as well as perform normal switching operations. For this reason the

followingprecautionsmustbeobserved:

1.Useonly the Casablanca W-32 wall control.

2. Do not use any additional control with your Inteli-Touch

fan(forexample,dimmer,fanspeedcontrol,etc.).

3. Do not use more than one fan per wall control.

4.Noother light xtures or electrical appliancesmay be

connected on the circuit controlled by the W-32 wall

control.

W-32isusedtodescribeeitherwhite(-11)orivorynish.
1.Removethescrewsandswitchplatefromtheexistingswitchbox.
2.Removethescrewsholdingtheswitchintheswitchbox.
3.Pulltheexistingswitchfromtheswitchboxtoexposethewirecon-
nections.
4.Removethetwowiresfromtheswitch.
5.Connect thetwo wiresjust removedfromthe switchto theW-32
wall control black wire and black/white stripe wire. Secure these
connections with wire nuts.
6. Connect the green ground wire coming from the back of the W-32
controltothegroundwireintheswitchbox.Securethesplicewith
a wire nut.
7.Install the W-32 in the wall box with thetwo long screws pro-
vided.
8.Installthewallplatewiththetwocolormatchedscrews.
To control the fan and lights from two locations (a three-way
circuit), use 2 W-32 wall controls.
1.Removethe screwsandswitch platefromthe existing
switchbox and thescrews holding the switch in the
switchbox.
2.Pulltheexistingswitchfrom theswitchboxtoexpose
the wire connections.
3. Determine which wire is connected to the common ter-
minal of the 3-way switch. (The terminal will be marked
on switch).
4.Removethewirefromthecommonterminalofthe3-way
switch. Connect this wire to the remaining black/white
striped wire on the W-32 control. Secure this splice with
a wire nut.
5.Removethetworemainingwiresfromthe3-wayswitch.
Connect one of these wires to a black wire on the W-32
control. Secure the splice with a wire nut. The remaining
wire is to be connected to the other black wire on the
W-32. Secure the splice with a wire nut.
6. Connect the green ground wire coming from the back of
theW-32controltothegroundwireintheswitchbox.
Secure the splice with a wire nut.
7.InstalltheW-32inthewallboxwiththetwolongscrews
provided.
8.Installthewallplatewiththetwoshortcolor-matched
screwsprovided.
9. Installation of the second W-32 control is identical.
Repeat steps 1 through 7.

CAUTION! Ensure power is turned OFF at the breaker

or fuse panel before starting installation.

CAUTION! Ensure power is turned OFF at the breaker
or fuse panel before starting installation.
NOTE: If wall control operation is reversed (fan switch controls lights and
light switch controls fan) turn off the power at the breaker or fuse panel,
then swap the two W-32 black/white stripe wires.
N0TE: If wall control operation is reversed (fan switch controls lights
and light switch controls fan) turn off the power at the breaker or
fuse panel, then swap the two W-32 black/white stripe wires.
INTELI•TOUCH DUAL W-32 INSTALLATIONINTELI•TOUCH SINGLE W-32 INSTALLATIONINTELI•TOUCH INSTALLING THE W-32 WALL CONTROL
Inteli•Touch®
R