HEATING CONNECTION

INSTALLATION

HEATING CONNECTION

The HeatMaster has two connections at the rear that can be used to connect a central heating circuit. Connecting a heating system may reduce the domestic hot water performance.

WARNING

The maximum pump motor load for the MCBA is 250 Watt. If a larger pump is required, install a relay between the pump and the MCBA.

Expansion

HeatMaster 71/101 models are fitted with two 10 litre expansion vessels, which are sized for hot water operation only. If a heating sys- tem is connected to the primary circuit, calculate the expansion capa- city necessary for the total volume of the heating system (Refer to the

technical instructions from a relevant manufacturer of expansion vessels.)

Example of a single circuit connection

1.3-way valve.

2.Heating pump.

3.Non-return valve.

4.Isolating valve.

5.Safety valve set to 3 bar with pressure gauge.

6.Expansion vessel.

7.Drain cock.

8.Primary circuit filling valve.

9.Controller.

8

 

 

9

 

 

 

1

2

3

4

 

 

4

5

6

7

WARNING

The pimary safety valve is supplied with a plastic tube connected to the discharge outlet - this is for test purposes only and should be removed. The safety valve should be connected to a drain using a metallic pipe eg. copper.

9