Measurement range:
Display range:
Negative values can be caused by readings produced based on a reference altitude or due to atmospheric conditions.
Display unit: 5 m (or 20 ft.)
Current Altitude Data:
Altitude Memory Data:
Manual save records: 14 (altitude, date, time)
Auto save values: High altitude (with month, day, time of reading), low altitude (with month, day, time of reading), cumulative ascent (with month, day, time of first reading), cumulative descent (with month, day, time of first reading)
Other: Reference altitude setting; Altitude graph; Altitude differential; Altitude auto measurement method (0’05 or 2’00)
Bearing Sensor Precision:Direction: Within ±10°
Values are guaranteed for a temperature range of
| Conditions (Altitude) | Altimeter | Barometer | |
|
| ± (altitude differential × 2% |
| |
| 0 to 6000 m | + 15 m) m |
| |
| 0 to 19680 ft. | ± (altitude differential × 2% | ± (pressure differential × 2% | |
Fixed |
| + 50 ft.) ft. | + 2 hPa) hPa | |
temperature |
| ± (altitude differential × 2% | ± (pressure differential × 2% | |
| 6000 to 10000 m | + 25 m) m | + 0.059 inHg) inHg | |
| 19680 to 32800 ft. | ± (altitude differential × 2% |
| |
|
| + 90 ft.) ft. |
| |
Effect of | 0 to 6000 m | ± 50 m every 10°C |
| |
0 to 19680 ft. | ± 170 ft. every 50°F | ± 5 hPa every 10°C | ||
variable |
|
| ± 0.148 inHg every 50°F | |
6000 to 10000 m | ± 70 m every 10°C | |||
temperature | ||||
| 19680 to 32800 ft. | ± 230 ft. every 50°F |
|
•Values are guaranteed for a temperature range of
•Precision is lessened by strong impact to either the watch or the sensor, and by temperature extremes.
Temperature Sensor Precision:±2°C (±3.6°F) in range of
Measuring unit: 1/100 second
Measuring capacity: 59' 59.99"
Measuring modes: Elapsed time, split time, two finishes
Measuring unit: 1 second
Countdown start time setting range: 60 minutes
World Time: 29 cities (29 time zones)
Other: Daylight Saving Time/Standard Time; Home City/World Time City switching
Illumination: LED
Other: Battery power indicator; Power Saving;
Power Supply: Solar cell and one rechargeable battery
Approximate battery operating time: 6 months (from full charge to Level 4) under the following conditions:
•Watch not exposed to light
•Internal timekeeping
•Display on 18 hours per day, sleep state 6 hours per day
•1 illumination operation (1.5 seconds) per day
•10 seconds of alarm operation per day
•10 compass operations per week
•10 hours of altimeter measurement, once per month
•Barometric pressure readings and graph updating every two hours (12 times per day)
Frequent use of illumination runs down the battery. Particular care is required when using the auto light switch (page
|
|
City Code Table
City |
| City | UTC Offset/ | |
Code |
| GMT Differential | ||
|
| |||
PAGO PAGO | (PPG) | Pago Pago | ||
HONOLULU | (HNL) | Honolulu | ||
ANCHORAGE | (ANC) | Anchorage | ||
LOS ANGELES (LAX) | Los Angeles | |||
DENVER | (DEN) | Denver | ||
CHICAGO | (CHI) | Chicago | ||
NEW YORK | (NYC) | New York | ||
SANTIAGO | (SCL) | Santiago | ||
RIO |
| Rio De Janeiro | ||
PRAIA | (RAI) | Praia | ||
UTC |
|
| 0 | |
LONDON | (LON) | London | ||
| ||||
PARIS | (PAR) | Paris | +1 | |
ATHENS | (ATH) | Athens | +2 | |
JEDDAH | (JED) | Jeddah | +3 | |
TEHRAN | (THR) | Tehran | +3.5 | |
DUBAI | (DXB) | Dubai | +4 | |
|
|
|
City |
| City | UTC Offset/ |
Code |
| GMT Differential | |
|
| ||
KABUL | (KBL) | Kabul | +4.5 |
KARACHI | (KHI) | Karachi | +5 |
DELHI | (DEL) | Delhi | +5.5 |
KATHMANDU | (KTM) | Kathmandu | +5.75 |
DHAKA | (DAC) | Dhaka | +6 |
YANGON | (RGN) | Yangon | +6.5 |
BANGKOK | (BKK) | Bangkok | +7 |
HONG KONG | (HKG) | Hong Kong | +8 |
TOKYO | (TYO) | Tokyo | +9 |
ADELAIDE | (ADL) | Adelaide | +9.5 |
SYDNEY | (SYD) | Sydney | +10 |
NOUMEA | (NOU) | Noumea | +11 |
WELLINGTON | (WLG) | Wellington | +12 |
•Based on data as of July 2010.