To a new (not sequential) PLU

PLU feature programming

There are two different methods you can use to assign features to PLUs.

With “Batch feature programming”, you can use a single operation to assign multiple features. “Individual feature programming”, on the other hand, let you assign features one-by-one. This method is recommended for programming of special features to individual PLUs.

Batch feature programming

When using this procedure to assign multiple features to PLUs, use 9-digit codes that you create using the following procedure.

Different program to the next PLU

PGM 63s6 PLU No. +6

(1 ~ 1200)

Mode Switch

6 :::::::;; 6 a 6 s

D9 D8 D7 D6 D5 D4 D3 D2 D1

Negative PLU

a

No = 0

 

 

 

 

Yes = 2

a+b =

:D9

Hash PLU

b

No = 0

 

 

 

 

Yes = 4

 

 

Single item sale

a

No = 0

 

 

 

 

Yes = 1

a+b =

:D8

Treat as subdepartment/PLU.

b

PLU = 0

 

 

 

 

Subdept. = 4

 

 

High digit limit specification (for subdepartment)

 

Significant

 

:D7

 

 

number

 

Taxable status 1

a

No = 0

 

 

 

 

Yes = 1

 

 

Taxable status 2

b

No = 0

a+b+c =

:D6

 

 

Yes = 2

Taxable status 3

c

No = 0

 

 

 

 

Yes = 4

 

 

Taxable status 4

 

No = 0

 

:D5

 

 

Yes = 4

 

Department link (00 ~ 24)

 

Significant

::D4 D3

 

 

numbers

Always “00”

 

 

;;D2 D1

 

 

 

 

 

 

 

 

 