Troubleshooting

In case of power failure

If the power supply to the cash register is cut by a power failure or any other reason, simply wait for power to be restored. The details of any ongoing transaction as well as all sales data in memory are protected by the memory backup batteries. (This is the reason to install the batteries.)

Power failure during a registration

The subtotal for items registered up to the power failure is retained in memory. You will be able to continue with the registration when power is restored.

Power failure during printing a read / reset report

The data already printed before the power failure is retained in memory. You will be able to issue a report when power is restored.

Power failure during printing of a receipt / journal

Printing will resume after power is restored. A line that was being printed when the power failure occurred is printed in full.

Other

The power failure symbol is printed and any item that was being printed when the power failure occurred is reprinted in full.

Important!

Once receipt / journal printing or printing of a report starts, it can be stopped only by interruption of power to the cash register.

Troubleshooting

When the L sign appears on the display

About the low battery indicator…

The following shows the low battery indicator.

 

 

If this indicator appears when you switch the cash register on, it can mean one

INIT

 

of three things:

 

•No memory backup batteries are loaded in the cash register.

llllllllll

•The power of the batteries loaded in the unit is below a certain level.

•The batteries loaded in the unit are dead.

RPT

T1 T2 T3 T4 TOTAL CHANGE

 

 

AMOUNT

 

Important!

Whenever the low battery indicator appears on the display, load a set of two new batteries as soon as possible. If there is a power failure or you unplug the cash register when this indicator appears, you will lose all of your sales data and settings.

BE SURE TO KEEP THE POWER CORD OF THE CASH REGISTER
PLUGGED IN WHENEVER YOU REPLACE THE BATTERIES.
103 E