Advanced Operations and Setups

To print the PLU unit price

OPERATION

REPORT

1.Turn to PGM mode.

2.Enter <6> and press <ST> key.

3.Enter <104> and press <ST> key.

4.Enter <start rec-#> and <CA> key.

5.Enter <end rec-#> and <CA> key.

 

 

 

 

P01....................

— Program read symbol

#0001 - #0010

— PLU range

PLU0001

0001-04

— PLU descriptor/rec-#/04

 

@1.00

— Unit price

PLU0002

0002-04

 

 

 

@2.00

 

 

 

 

 

 

To print the PLU descriptor

OPERATION

REPORT

1.Turn to PGM mode.

2.Enter <6> and press <ST> key.

3.Enter <204> and press <ST> key.

4.Enter <start rec-#> and <CA> key.

5.Enter <end rec-#> and <CA> key.

 

 

 

 

P02 ....................

— Program 2 mode symbol

#0001 - #0010

— PLU range

— PLU character

PLU0001

0001-04

PLU0002

0002-04

 

 

PLU0003

0003-04

 

 

 

 

 

 

To print the PLU program

OPERATION

REPORT

1.Turn to PGM mode.

2.Enter <6> and press <ST> key.

3.Enter <304> and press <ST> key.

4.Enter <start rec-#> and <CA> key.

5.Enter <end rec-#> and <CA> key.

P03 ....................

— Program 3 mode symbol

#0001 - #0010

— PLU range

PLU0001

0001-04

— PLU descriptor/rec-#/file-#

 

00000000000000

— Address code 01 ~ 10, 18 program

11-66

000000

— Address code 11 program

13-66

<- 0001-28

— Address code 13 program

14-66

0

— Address code 15 program

15-66

@1234.56

PLU0002

0002-04

 

To print the key allocation program

OPERATION

REPORT

1.Turn to PGM mode.

2.Enter <4> and press <ST> key.

3.Press <ST> key.

P04 ....................

— Program read symbol

1 -----------------------

 

000015-02— Function character/rec-#/file-#

011-096— Hard key code/function code

.0009-02

012-098

CASH0004-02 013-001

E98