CBM-710/720/730/750 User ’s Manual

9.SERIAL INTERFACE

9.1Specifications

a)Synchronism

b)Baud rate: RS-232C type Current Loop type

:Asynchronous

:110, 150, 300, 600, 1200, 2400, 4800, 9600BPS (Selected by user)

:110, 150, 300, 600, 1200BPS (Selected by user)

c) Composition of one word:

 

 

 

Start bit

: 1bit

 

 

 

Data bit

: 7 or 8 bits (selected by user)

 

Parity bit

: Odd, even or no parity (Selected by user)

Stop bit

: 1bit or more

 

 

d) Signal Polarity :

 

 

 

 

RS-232C type

: *Mark

= Logic "1"

(-3V to -12V)

 

*Space

= Logic "0"

(+3V to +12V)

Current Loop type

: *Mark

= Logic "1"

(Current ON)

 

*Space

= Logic "0"

(Current OFF)

e) Received Data:

 

 

 

 

RS-232C & Current Loop (RD signal)

 

 

 

*Mark = 1

 

 

 

*Space = 0

 

 

f) Receiving Control (DTR signal)

 

 

 

RS-232C

: *Mark:

Data Transfer not possible

 

*Space:

Data Transfer possible

Current Loop:

*Mark (Current ON):

 

Data Transfer possible

 

*Space (Current OFF):

Data Transfer not possible

g) Transmission Control (TD signal)

 

 

 

DC1 code (11H) "X" ON :

Data Receiving possible

DC3 code (13H) "X" OFF:

Data Receiving not possible

However, this is valid only for type B input buffer (7K).