TECHNICAL INFORMATION FOR THE INSTALLER

In order to install the cooktop into the kitchen fixture, a hole with the dimensions shown in fig. 19 has to be made, bearing in mind the following:

Within the unit, between the bottom of the cooktop and the upper surface of a shelf there must be a clearance of at least 30 mm.

It is absolutely essential that you place a separator between the base of the cooktop and the built-in unit or the oven;

The cooktop must be kept no less than 200 mm away from any side wall (fig. 18).

There must be a distance of at least 60 mm between the back side of the cut-out and the back of the countertop.

There must be a distance of at least 650 mm between the hob and any wall cup- board or extractor hood positioned immediately above (see fig. 18).

If the hob is installed over a built-in oven, the built-in oven shall be provided with cooling fan.

The two appliances shall be connected to the gas/electric supply with independent connections.

Figure 18

20

 

450 mm

 

200

mm

min

 

 

 

650 mm

500

mm

 