CDA HVG95 manual GAS Connector, Connection to the GAS Supply

Models: HVG95

1 36
Download 36 pages 18.99 Kb
Page 26
Image 26

GAS CONNECTOR

GB Cat: II 2H3+

The fitting (fig. 23) is made up of:

1 nut “A”

1 elbow fitting “C”

gasket “F”

CONNECTION TO THE GAS SUPPLY

Be careful when flexible pipes are used that they do not come into contact with moving parts.

To maintain the thickness of 3 cm, the hob is fitted with a channel to contain the connection pipe.

The gas inlet union can be turned in the direction required after the elbow fitting “C” and nut “A” connection (figure 23) has been slackened (Fig. 24).

Never put it in the horizontal or vertical position.

Never attempt to turn the elbow “C” without having first slackened off the relative lock nut “A”.

The gasket “F” (fig. 23) guarantees the seal of the gas connection.

It is recommended that it be replaced whenever it shows even the slightest deformation or imperfection.

Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing the solution over the connection. The presence of bubbles will indicate a leak. If there is a leak, tighten the fitting and then recheck for leaks.

IMPORTANT! Do not use a naked flame to test for leaks

Figure 23

Figure 24

1/2" G cylindrical

 

1/2" G cylindrical

(ISO 228-1) male

 

(ISO 228-1) female

C

F

A

 

1/2" G conical

 

(ISO 7-1) male

26

 

 