Table for the choice of the injectors
GB |
|
|
| Cat: II 2H3+ | |
|
|
|
|
| |
| Nominal | Reduced | G 30 - | G 20 | |
| G 31 - 37 mbar | 20 mbar | |||
BURNERS | Power | Power | |||
|
| ||||
Ø injector | Ø injector | ||||
| [kW] | [kW] | |||
| [1/100 mm] | [1/100 mm] | |||
|
|
| |||
|
|
|
|
| |
Auxiliary (A) | 1,00 | 0,30 | 50 | 72 (X) | |
|
|
|
|
| |
1,75 | 0,45 | 65 | 97 (Z) | ||
|
|
|
|
| |
Rapid (R) | 3,00 | 0,75 | 85 | 115 (Y) | |
|
|
|
|
| |
3,50 | 1,50 | 95 | 135 (T) | ||
|
|
|
|
|
INCREASE OF AIR NECESSARY FOR GAS COMBUSTION (2 m3/h x kW)
BURNERS | Air necessary for combustion [m3/h] |
Auxiliary (A) | 2,00 |
|
|
3,50 | |
|
|
Rapid (R) | 6,00 |
|
|
7,00 | |
|
|
Lubrication of the gas taps
The operations must be executed by a qualified technician.
IMPORTANT
All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the
43