Electrical feeder cable connection

Electrical feeder cable connection

To connect the feeder cable to the cooker it is necessary to:

Remove the 2 screws that hold shield A behind the cooker.

Open completely the cable clamp D.

Insert the feeder cable into the cable save P. The supply cable must be of a suitable size for the current require- ments of the appliance; see the section “Feeder cable section”.

Connect the phase and earth cables to terminal B according to figures 45 and 46.

Pull the feeder cable and block it with the cable clamp D.

Re-mount shield A.

N.B. The earth conductor must be left about 3 cm longer than the others.

Feeder cable section type H05RRF

230 V

3 x 2,5 mm2 (**)

(**)Connection with wall box connection.

 

 

 

 

 

 

 

 

230 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1 N

 

PE

 

 

 

 

 

 

 

 

 

 

(L2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PE

 

 

 

 

 

 

Earth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

Neutral

 

 

 

 

 

L

 

 

 

 

 

 

Live

 

 

 

Fig. 46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 