Installation

UVSTR / UVCVR Series Vent-Free Fireboxes

Installation

Planning

In planning the installation for the firebox it is neces- sary to determine where the unit is to be installed and whether optional accessories are desired. Gas supply piping should also be planned.

These models may NOT be installed in a bedroom or bathroom.

Glass doors are NOT available for these fireboxes.

The firebox can be mounted on any of the following surfaces:

A flat hard combustible surface.

A raised platform of combustible or noncombustible material.

A concrete block or other solid object placed be- neath each of the four corners of the appliance.

If the firebox is installed directly on carpeting, tile or other combustible material other than wood flooring, it should be installed on a metal or wood panel extending the full width and depth of the unit.

At this point, you should have decided what compo- nents to include in your installation, and where the firebox is to be located. If this has not been done, stop and consult your dealer for planning assistance.

Framing

Firebox framing can be built before or after the firebox is set in place. Framing should be positioned to ac- commodate wall covering and firebox facing material. The firebox framing should be constructed of 2 x 4 or heavier lumber. The framing headers may rest on the top of the firebox standoffs Refer to Figs. 1 and 2 for firebox framing dimensions.

Anchor Firebox in Position

To prevent shifting of the firebox and to maintain sealing (described later), anchor the firebox. Two methods are possible for these fireboxes.

One method is to use the eight fastening tabs (four with cove model) provided with the firebox. (Fig. 5) The firebox may be secured to the vertical framing members with these tabs and nails or other suitable fasteners.

The second method uses the standoffs at the front of the firebox. A nail may be installed through the standoffs and into the header to stabilize the top of the firebox. (Fig. 5)

6

Installing Outside Air Kit

An outside air kit may be installed in all UVSTR/CVR Series fireboxes. If desired, or if local codes man- date the use of an air kit, then an AKU2 is required to complete the installation (from air kit to out-of-doors). If the outside air kit is to be used, the AKU2 MUST be installed BEFORE the fireplace is enclosed. Refer to the AKU2 instructions for field installation.

 

Nail Top

 

Standoffs

 

Nail Eight

 

Side-Nailing

 

Flanges

 

UVSTR36

 

Nail Top

 

Standoffs

 

Nail Four

 

Side-Nailing

 

Flanges

 

UVCVR36

 

FP680

Fig. 5

Adjustable drywall strip (nailing flange).

 

7412960

Page 6
Image 6
CFM UVSTR36, UVCVR36 Installation, Planning, Framing, Anchor Firebox in Position, Installing Outside Air Kit, 7412960