CFM Corporation 2460 Stove and Chimney Connector Clearance Charts, Dutchwest, Protected Surfaces

Models: 2461 2460 2462

1 32
Download 32 pages 1.09 Kb
Page 13
Image 13
Stove and Chimney Connector Clearance Charts

Dutchwest

Stove and Chimney Connector Clearance Charts

Model 2460 Small Convection, and Model 2461 Large Convection:

 

 

 

UNPROTECTED SURFACES

 

PROTECTED SURFACES

 

 

 

 

 

 

 

 

Corner

 

 

 

 

 

Corner

 

 

 

Parallel Installations

Installations

 

Parallel Installations

Installations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove Clearance

 

Side

 

Rear

 

Corner

 

Side

 

Rear

 

Corner

 

No heat shields

[A]

22” (560 mm)

[B]

24” (610 mm)

[C]

18” (460 mm)

[D] 12” (300 mm)

[E] 14” (360 mm)

[F] 10” (250 mm)

 

Rear exit, rear h.s.

[G]

22” (560 mm)

[H]

14” (360 mm)

 

N/A

[I]

12” (300 mm)

[J] 12” (300 mm)

 

N/A

 

Top exit1, rear h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall connector

[K]

22” (560 mm)

[L]

24” (610 mm)

[M] 18” (460 mm)

[N]

12” (300 mm)

[O] 14” (360 mm)

[P] 10” (250 mm)

 

No connector h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit1,2 , rear h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall connec-

[K]

22” (560 mm)

[L] 14” (360 mm)

[M] 15” (380 mm)

[N]

12”(300 mm)

[O] 12” (360 mm)

[P] 8” (200 mm)

 

tor with connector h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit1 , rear h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Double-wall connector

[K]

22” (560 mm)

[L] 19” (480 mm)

[M] 15” (380 mm)

[N]

12” (300 mm

[O]

11” (280 mm)

[P] 8” (200 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney Connector Clearance:

 

 

 

 

 

 

 

 

 

 

 

Single-wall connector

 

19” 480 mm)

 

 

 

9” (230 mm)

 

 

 

No connector h.s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall2connector

 

9” (360 mm)

 

 

 

7” (180 mm)

 

 

 

With connector h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double-wall connector

 

14” (360 mm)

 

 

 

6” (150 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front Clearance to Combustibles:

 

48” (1220 mm) (All Installations)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model 2462 Extra-Large Convection:

 

 

 

 

 

 

 

 

 

 

 

UNPROTECTED SURFACES

 

PROTECTED SURFACES

 

 

 

 

 

 

 

 

Corner

 

 

 

 

 

Corner

 

 

 

Parallel Installations

Installations

 

Parallel Installations

Installations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stove Clearance

 

Side

 

Rear

 

Corner

 

Side

 

Rear

 

Corner

 

No heat shields

[A]

20” (510 mm)

[B]

23” (580 mm)

[C]

18” (460 mm)

[D]

18” (460 mm)

[E]

18” (460 mm)

[F]

17” (430 mm)

 

Rear exit, rear h.s.

[G]

20” (510 mm)

[H]

18” (460 mm)

 

N/A

[I]

18” (460 mm)

[J]

12” (300 mm)

 

N/A

 

Top exit1, rear h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall connector

[K]

20” (510 mm)

[L]

23” (580 mm)

[M]

18” (460 mm)

[N]

18” (460 mm)

[O]

18” (460 mm)

[P]

17” (430 mm)

 

No connector h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit1,2 , rear h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall connec-

[K]

20” (510 mm)

[L]

18” (460 mm)

[M]

17” (430 mm)

[N]

18” (460 mm)

[O]

12” (300 mm)

[P]

15” (380 mm)

 

tor with connector h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Top exit1 , rear h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Double-wall connector

[K]

20” (510 mm)

[L]

14” (360 mm)

[M]

16” (410 mm)

[N]

18” (460 mm)

[O]

12” (300 mm)

[P]

15” (380 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chimney Connector Clearance:

 

 

 

 

 

 

 

 

 

 

 

Single-wall connector

 

18” (460 mm)

 

 

 

13” (330 mm)

 

 

 

No connector h.s

 

 

 

 

 

 

 

 

 

 

 

 

 

Single-wall2connector

 

13” (330 mm)

 

 

 

7” (180 mm)3,4

 

 

 

With connector h.s.

 

 

 

 

 

 

 

 

 

 

 

 

 

Double-wall connector

 

8” (200 mm)

 

 

 

6” (150 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Front Clearance to Combustibles:

 

48” (1220 mm) (All Installations)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Shielding for a top exit stove must include a shield insert to protect the area behind the flue collar.

2 Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.

3 All installations venting straight up to a factory built chimney require a 24” (610 mm) diameter or square ceiling heat shield. The ceiling heat shield should be 24 gauge sheet metal or equivalent mounted on 1” (25 mm) non-combustible spacers 1” (25 mm) below ceiling.

4 Chimney connector heat shields must extend to within 1” (25 mm) or less of the ceiling heat shield for installations venting straight up to a factory-built chimney. In top exit installations using an elbow to vent to the rear, the chimney connector must be shielded over the entire vertical length.

5 If a single-wall oval-to-round adaptor is used, a shield must be used to protect combustibles to the rear of the adaptor.

7001135

13

Page 13
Image 13
CFM Corporation 2460 Stove and Chimney Connector Clearance Charts, Dutchwest, Unprotected Surfaces, Protected Surfaces