CFM Corporation 2461, 2462, 2460 manual Dutchwest, Unprotected Surfaces, Protected Surfaces, 7001135

Models: 2461 2460 2462

1 32
Download 32 pages 1.09 Kb
Page 14
Image 14
Chimney Connector

Dutchwest

Distance from Center of Flue Collar to Wall in Top-Exit Installations

Dutchwest Convection Heaters equipped with rear heat shields

NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue collar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the wall protector.

Manual backgroundManual background A BC Manual background

D

E

 

F

ST427

 

 

 

 

 

UNPROTECTED SURFACES

PROTECTED SURFACES

 

 

 

 

 

 

 

Corner

 

 

Corner

 

 

 

 

 

Parallel Installations

Installations

Parallel Installations

Installations

 

 

 

 

 

 

 

 

 

 

 

Chimney Connector

 

Side

Rear

Corner

Side

Rear

Corner

 

 

 

 

 

 

 

 

 

 

 

MODEL 2460 (Small Convection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listed, Approved

 

 

 

 

 

 

 

 

 

Double-wall

 

[A] 33” (840 mm)

[B] 18” (460 mm)

[C] 25” (640 mm)

[D] 23” (580 mm)

[E] 10” (250 mm)

[F] 15” (380mm)

Single Wall, with

 

 

 

 

 

 

 

 

 

Connector Heat Shields

 

[A] 33” (840 mm)

[B] 13” (330 mm)

[C] 22” (560 mm)

[D] 23” (580 mm)

[E] 11” (580 mm)

[F] 15” (380 mm)

Single Wall, without

 

 

 

 

 

 

 

 

 

Connector Heat Shields

 

[A] 33” (840 mm)

[B] 23” (580 mm)

[C] 25” (640 mm)

[D] 23” (580 mm)

[E] 13” (330 mm)

[F] 17” (430 mm)

 

 

 

 

 

 

 

 

 

 

 

MODEL 2461 (Large Convection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listed, Approved

 

 

 

 

 

 

 

 

 

Double-wall

 

[A] 35” (890 mm)

[B] 18” (460 mm)

[C] 27” (690 mm)

[D] 25” (640 mm)

[E] 10” (250 mm)

[F] 17” (430 mm)

Single Wall, with

 

 

 

 

 

 

 

 

 

Connector Heat Shields

 

[A] 35” (890 mm)

[B] 13” (330 mm)

[C] 24” (610 mm)

[D] 25” (640 mm)

[E] 11” (280 mm)

[F] 17” (430 mm)

Single Wall, without

 

 

 

 

 

 

 

 

 

Connector Heat Shields

 

[A] 35” (890 mm)

[B] 23” (580 mm)

[C] 27” (690 mm)

[D] 25” (640 mm)

[E] 13” (330 mm)

[F] 19” (480 mm)

 

 

 

 

 

 

 

 

 

 

 

MODEL 2462 (Extra-Large Convection)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Listed Approved

 

 

 

 

 

 

 

 

 

Double-Wall

 

[A] 35” (890 mm)

[B] 13” (330 mm)

[C] 26” (660 mm)

[D] 33” (660 mm)

[E] 11” (280 mm)

[F] 25” (640 mm)

Single Wall, with

 

 

 

 

 

 

 

 

 

Heat Shields

 

[A] 35” (890 mm)

[B] 17” (430 mm)

[C] 29” (740 mm)

[D] 33” (840 mm)

[E] 11” (280 mm)

[F] 25” (640 mm)

Single Wall, without

 

 

 

 

 

 

 

 

 

Heat Shields

 

[A] 35” (890 mm)

[B] 22” (560 mm)

[C] 33” (840 mm)

[D] 33” (840 mm)

[E] 17” (430 mm)

[F] 27” (690 mm)

 

 

 

 

 

 

 

 

 

 

 

 

14

7001135

Page 14
Image 14
CFM Corporation 2461, 2462, 2460 manual Dutchwest, Unprotected Surfaces, Protected Surfaces, 7001135, Chimney Connector