Left Air Duct | Snapstat |
| |
| ST671 |
Fig. 12 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan before gas line connection.
9.After sliding the firebox in place, the rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 13)
•Remove the plug from the rheostat bracket.
•Insert the switch box shaft through the hole in the back of the right side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.
•Attach the control knob to the rheostat shaft.
•Use the wire tie to secure the fan and rheostat wire harnesses together.
10.Plug the power cord into a standard grounded 110 volt household outlet. If the fan control knob is not turned to the OFF position, the fan will turn on when the temperature at the snapstat reaches approximately 109°F.
|
|
| Rheostat | |
| Retaining Nut |
|
| |
| Control Knob |
|
| |
|
|
|
| ST758 |
Fig. 13 | Attach rheostat to left side of valve. | |||
|
| MOTOR |
|
|
| BLK | BLK | BLK | SNAPSTAT |
|
|
| ||
|
| BLK |
| WHT |
| WHT | GRN | ON/OFF |
|
| RHEOSTAT |
| ||
|
| POWER |
|
|
|
|
|
| ST196 |
Fig. 14 | #2767 / FK26 fan wiring diagram. | |||
30002008 |
|
|
|
Dutchwest Natural Vent Gas Heater
Venting System Assembly
The venting collar is on the sheet metal draft hood/heat exchanger assembly, over the firebox. Use a
The stove includes a spill switch. Operating this stove when not connected to a properly installed and main- tained venting system, or tampering with or disconnect- ing the spill switch, can result in carbon monoxide (CO) poisoning and possible death.
The stove includes a bracket for installing decorative 6” (150mm) round stove pipe around the
If the installation includes decorative stove pipe around the venting system, make a cardboard template of the decorative pipe by tracing its circumference. Put this template in the flue recess in the stove top. Position the template to fit well against the front of the recess. (Fig. 16) Use this template to locate the bracket to hold the decorative pipe. Depending on spacing, the bracket may fit inside the decorative pipe without interfering with the vent system. Fasten the bracket to the draft hood/heat exchanger assembly with a sheet metal screw.
| Sheet Metal Screw |
Template | Bracket |
| ST777 |
Fig. 16 Use a template to locate the bracket for decorative pipe to surround the
Insert the
| ST778 |
Fig. 17 | Attach the |
| 9 |