Inspire Electric Fireplace

Fireplace Dimensions

Minimum Shelf Height

36”

(To Heater Main body)

(914 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24����

(615 mm )

23���"

(594 mm)

 

35�����” (910 mm)

 

 

5�����

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9���

[Heater Main Body Width 32���” (832 mm)]

(145 mm)

 

 

 

 

 

 

 

 

 

(250 mm)

From Floor

 

 

 

 

 

 

 

 

 

 

Electrical Specifications

Voltage

120V ac, 60 Hz

Total Amps

7.9 Amps

Total Watts

1050W

Heater Rating

2 x

500W

Illumination

2 x

20W Low Energy Bulb

Electrical Connection

A 15 amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is in operation. The unit comes standard with a 6 ft. (1.8 m) long three wire cord, exiting the left side of the fireplace. Plan the installa- tion to avoid the use of an extension cord. Extension cords are for temporary use only. If an extension cord must be used, it must be UL/CSA certified, rated at 15A (1875W), 125V maximum with 14 AWG minimum and constructed of two current carrying conductors with ground. A heavy duty extension cord with the shortest length possible for the connection is recommended and must not be longer than 50 ft. (15.2 m). Do not coil or cover the extension cord.

WARNING

Always confirm that the electrical outlet wiring is in compliance with all applicable local and national building codes and electrical code requirements to avoid the risk of fire or electric shock.

If the fireplace should be exposed to water, imme- diately turn off the main power supply and remove the power plug from the outlet. Never use the fire-

place until it has first been inspected if any portion of it has been exposed to water. Always utilize a qualified service technician to inspect the fireplace and to replace any electrical system components that may have been damaged by water.

Grounding Instructions

This heater is for use on 120 volts. The cord has a plug as shown at A in Figure 1. An adapter as shown at C is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a per- manent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.

A

 

 

Cover of

Grounding Pin

 

Grounded

B

Outlet Box

 

 

 

C

 

Adapter

 

Metal Screw

 

 

 

Grounding Means

FP1636

 

 

Fig. 1 Grounding methods.

4

10009472

Page 4
Image 4
CFM Corporation ICVCEFP01 Fireplace Dimensions, Electrical Specifications, Electrical Connection, Grounding Instructions