3.Vent System Termination
Before installing Power Venter, determine location of vent system termination.
4.Location of the Fan
To keep the noise level to a minimum, the fan should be located as far from the appliance as possible.
A storage cupboard, or laundry area are preferred locations. Permanent access for inspection and servicing must be provided.
5.All portions of the vent system under positive pres- sure during operation (on the outlet side of the Power Venter) shall be designed and installed so as to prevent leakage of flue or vent gases into a build- ing.
General Code Requirements
The exit terminal shall be so arranged that flue gases are not directed so as to jeopardize the safety of people, overheat combustible structures or enter buildings, and that proper clearances are maintained. Always consult your local codes and authorities. In the absence of such codes follow the current installa- tion codes for gas burning appliances
Also see Diagram A - Vent Termination Locations.
Majestic® Fireplaces Power Venting System
Power Venter Specifications
Electrical |
|
Motor voltage | 115 |
Control Circuit Voltage | 24 |
Hz | 60 |
RPM | 3000 |
Watts | 95 |
Amps | 1.26 |
Thermal Protection | Yes |
Mechanical |
|
Shaded Pole Motor | Yes |
Int. Fan Cooled | yes |
Shaft Diameter (inch) | 313 |
Bearings | Sleeve Type |
51810 | 3 |