3.Vent System Termination

Before installing Power Venter, determine location of vent system termination.

4.Location of the Fan

To keep the noise level to a minimum, the fan should be located as far from the appliance as possible.

A storage cupboard, or laundry area are preferred locations. Permanent access for inspection and servicing must be provided.

5.All portions of the vent system under positive pres- sure during operation (on the outlet side of the Power Venter) shall be designed and installed so as to prevent leakage of flue or vent gases into a build- ing.

General Code Requirements

The exit terminal shall be so arranged that flue gases are not directed so as to jeopardize the safety of people, overheat combustible structures or enter buildings, and that proper clearances are maintained. Always consult your local codes and authorities. In the absence of such codes follow the current installa- tion codes for gas burning appliances CSA-B149.1 in Canada or ANSI Z223.1/NFPA 54 in the US.

Also see Diagram A - Vent Termination Locations.

Majestic® Fireplaces Power Venting System

Power Venter Specifications

Electrical

 

Motor voltage

115

Control Circuit Voltage

24

Hz

60

RPM

3000

Watts

95

Amps

1.26

Thermal Protection

Yes

Mechanical

 

Shaded Pole Motor

Yes

Int. Fan Cooled

yes

Shaft Diameter (inch)

313

Bearings

Sleeve Type

51810

3