Installation Step 6

Install the Multi-Function

Door Control Panel

Strip 1/4" of insulation from one end of the bell wire; connect the wire to the two screw terminals on the back of the door control by color: white to 2 and white/red to 1.

Locate the door control within sight of the door at a minimum height of 5 feet where small children cannot reach, and away from all moving parts of the door and door hardware. Fasten the Multi-Function Door Control securely with 6ABx1" screws. If installing into drywall, drill 5/32" holes and use the anchors provided.

Run the bell wire up the wall and across the ceiling to the opener. Use insulated staples to secure the wire in several places. Be careful not to pierce the wire with a staple, creating a short.

Receiver terminal screws and the antenna are located on the right panel of the opener. Position the antenna wire as shown.

Then connect the bell wire to the opener terminal screws: white to 2 and white/red to 1.

Remember to affix the User Safety Instruction label to the wall near the door control, and the Maintenance Instruction label in a prominent location on the inside of the garage door.

If the label adhesive will not adhere to your garage wall surface (or becomes loose with time) use tacks to secure the label alongside the door control.

Page 28 explains how to operate the opener using the lighted push button and the Lock & Light features available on the Multi-Function Door Control Panel.

Hardware Shown Actual Size

6AB x 1" Screw

 

Insulated

Multi-Function Door Control

Dry Wall Anchors

Staples

WARNING

Children operating or playing with a garage door opener can injure themselves or others. The garage door could close and cause serious injury or death. Install the door control (or any additional push buttons) out of the reach of children and away from all moving parts of the door and door hardware, but where the garage door is visible. Do not allow children to operate the push button(s) or the remote control transmitter(s).

A moving garage door could injure someone under it. Activate the opener only when the door is properly adjusted, you can see it clearly, and there are no obstructions to door travel.

Do NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.

See Safety Reversing Sensor Instructions beginning on page 17.

Outside Keylock Accessory Connections

To opener terminal screws: white to 2; white/red to 1

Multi-Function

Door Control Panel

Terminal Screws

RED

WHITE

1

2

 

Lock Button

LOCK

LIGHT

Light Button

 

Door Control

Button

Multi-Function

Door Control PanelRight Panel

of Opener

Opener

Terminal Screws

TO PROGRAM RECEIVER CODE

 

1

 

2

 

3

 

 

 

FOR EACH REMOTE CONTROL

 

 

 

 

 

 

1. Press and HOLD remote control

 

 

 

 

 

 

 

 

 

 

transmitter push button.

 

 

 

 

 

 

 

 

 

 

2. Press receiver code button. The opener

 

 

 

 

 

 

 

 

 

 

light will flash once.

 

 

 

 

 

 

 

 

 

 

3. Release transmnitter button. Opener

 

 

 

 

 

 

 

 

 

 

has learned code.

 

 

 

 

 

 

 

 

 

 

TO ERASE ALL RECEIVER CODES

 

 

 

9

1

9

 

1

1. Press and HOLD receiver code button.

 

 

 

 

 

 

 

 

 

 

Green indicator light alongside will turn

 

 

 

7

3

7

3

 

ON.

 

 

 

 

5

 

 

5

 

 

2. When light turns OFF (about 6

 

 

 

 

KG

 

 

KG

 

 

 

 

 

 

seconds) ALL codes are erased from

 

 

 

 

 

 

opener memory.

 

 

This device complies

WARNING: To reduce the risk of severe injury

 

 

 

with FCC Rules Part

or death by entrapment, when adjusting either

 

 

 

15. Operation of this

the force or limits of travel controls ensure that

 

 

 

the door reverses on a 1 inch object (or a 2 x 4

 

 

 

device is subject to the

board laid flat). See instructions for proper

 

 

 

following conditions:

adjustment procedure.

 

 

 

 

 

 

 

 

1. This device may

AVERTISSEMENT: Pour réduire les risques de

 

 

 

not cause harmful

blessures mortelles par happement, après tout

 

 

 

interference. 2. This

réglage de la force de déclenchement ou des

 

 

 

device must accept

seuils de fin de course s'assurer que le sens de

 

 

 

any interference

la course s'inverse lorsque la porte entre en

 

 

 

that may be received,

contact avec un object de 13 mm (1 po) de

 

 

 

including interference

hauteur (ou un madrier de 2 x 4 de section, à

 

 

 

that may cause

plat) posé sur le sol. Effectuer les reglages

 

 

 

undesired operation.

selon les procédures décrites dans la notice.

 

 

 

 

 

PART NO:

 

Nº DE PIÈCE:

 

 

 

 

 

D.O.C. CERT. NO.

DATE:

 

 

 

 

 

M.D.C. CERT. NO.

132C2105-1

Antenna