Planning

Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener.

SECTIONAL DOOR INSTALLATION

Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 19 for details.

Header Wall

Vertical

Centerline

of Garage Door

 

FINISHED CEILING

Support bracket & fastening hardware is required.

See page 12.

Slack in chain tension is normal when garage door is closed.

Extension Spring

Torsion OR

Spring

OR

One-Piece Door-Extension Spring

Header Wall

Motor Unit

Access

Door

 

Track

 

— —

Door

 

 

 

— —

 

 

 

Safety

 

Gap between floor

Reversing

Safety Reversing Sensor

and bottom of door

Sensor

must not exceed 1/4" (6 mm)

 

Wall- mounted Door Control

ONE-PIECE DOOR WITHOUT TRACK

 

FINISHED CEILING

 

 

 

 

Support bracket

 

 

& fastening

 

 

 

 

hardware is required.

 

 

See page 12.

Slack in chain tension

 

is normal when

 

garage door is closed.

 

Header

 

Wall

 

Wall- mounted Door Control

Access

Door

Motor Unit

ONE-PIECE DOOR WITH TRACK

Slack in chain tension is normal when garage door is closed.

Access

Door

Safety

Reversing Sensor

 

Gap between floor and bottom of

Safety

door must not exceed 1/4" (6 mm)

Reversing Sensor

Safety

Reversing Sensor

Gap between floor and bottom of door must not exceed 1/4"

Safety

Reversing Sensor

(6 mm).

4