INSTALLATION STEP 6
Install the Control ConsoleLocate control console within sight of door, at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided. For
CAUTION: Continuous exposure of the control console to temperatures below
NOTE: The functional temperature range of the control console is between
SPECIAL NOTE: Only one 398LMC can be connected to each garage door opener. If additional wall controls are desired to operate the same garage door opener, it is recommended to use model 378LMC wireless wall control as the secondary control console.
1. Strip 7/16" (11 mm) of insulation from one end of bell |
wire and connect to the two screw terminals on back of |
control console by color: white wire to the W (2) and |
white/red wire to the R (1) (Figure 2). |
2. Remove push bar cover by gently prying at the lower/ |
middle portion of the cover with a small |
To prevent possible SERIOUS INJURY or DEATH from electrocution:
•Be sure power is not connected BEFORE installing door control.
•Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
•Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet (1.5 m), and away from all moving parts of door.
•NEVER permit children to operate or play with door control push buttons or remote control transmitters.
•Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
•ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
Screw | Insulated |
(std installation) | Staples |
Screw |
|
Drywall Anchors |
screwdriver. Fasten with 6AB x |
screws (drywall installation) or |
screws (into gang box) as follows: |
• Install bottom screw, allowing 1/8" (3 mm) to protrude |
above wall surface. |
• Position bottom of control console on screw head and |
slide down to secure. Adjust screw for snug fit. |
• Drill and install top screw with care to avoid cracking |
plastic housing. Do NOT overtighten. |
• Replace cover by inserting top tabs first and then |
snap cover in place. |
3. (For standard installations ONLY) Run bell wire up |
wall and across ceiling to motor unit. Use insulated |
staples to secure wire in several places. Do NOT |
Figure 1
REMOVE & REPLACE COVER
To Replace Insert
Top Tabs First
Push Bar Cover
LOCK | LIGHT |
LOCK
Figure 2 | ||||
| Bell Wire | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24 Volt Bell Wire
LIGHT
Push Bar
pierce wire with a staple, creating a short or open |
circuit. |
4. Strip 7/16" (11 mm) of insulation from end of bell wire. |
Connect bell wire to the |
motor unit: white to white and white/red to red |
(Figure 3). |
NOTE: If you have any trouble with the operation of the buttons, loosen the top mounting screw. DO NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
|
| Door |
|
|
|
| Control |
|
|
|
| Terminal |
|
|
R | W | Screws | LOCK |
|
1 | 2 |
|
| |
|
|
| Lock | LOCK |
|
|
|
| |
(BACK VIEW) | Button Light | |||
|
|
|
| Button |
Figure 3 |
| Door Control |
| To release or insert wire, |
| Connections |
| push in tab with | |
|
|
| ||
|
|
|
| screwdriver tip |
Red White Grey
7/16" (11 mm)
Strip wire 7/16" (11 mm)
13