MOUNTING AND WIRING THE SAFETY REVERSING

Figure 5

 

SENSORS

 

 

 

 

Wing Nut

• Slide a 1/4"-20x1/2" carriage bolt head into the slot on

 

 

1/4"-20

 

each sensor. Use wing nuts to fasten sensors to

 

 

 

brackets, with lenses pointing toward each other across

 

 

 

the door. Be sure the lens is not obstructed by a bracket

 

 

 

extension (Figure 5).

 

Carriage Bolt

 

Finger tighten the wing nuts.

 

1/4"-20x1/2"

Lens

 

 

 

 

 

Run the wires from both sensors to the opener. Use

TROUBLESHOOTING THE SAFETY REVERSING

 

insulated staples to secure wire to wall and ceiling.

 

SENSORS

 

Strip 7/16" (11 mm) of insulation from each set of wires.

 

1. If the sending eye indicator light does not glow steadily

 

Separate white and white/black wires sufficiently to

 

after installation, check for:

 

 

connect to the opener quick-connect terminals. Twist

 

 

• Electric power to the opener.

 

 

like colored wires together. Insert wires into

 

 

• A short in the white or white/black wires. These can

 

quick-connect holes: white to white and white/black to

 

grey (Figure 6). To release or insert wire, push in tab

occur at staples, or at opener connections.

 

with screwdriver tip.

 

• Incorrect wiring between sensors and opener.

ALIGNING THE SAFETY REVERSING SENSORS

• A broken wire.

 

Plug in the opener. The indicator lights in both the

2. If the sending eye indicator light glows steadily but the

 

sending and receiving eyes will glow steadily if wiring

receiving eye indicator light doesn’t:

 

connections and alignment are correct.

• Check alignment.

 

The sending eye amber indicator light will glow regardless

• Check for an open wire to the receiving eye.

of alignment or obstruction. If the green indicator light in

3. If the receiving eye indicator light is dim, realign either

the receiving eye is off, dim, or flickering (and the invisible

sensor.

 

light beam path is not obstructed), alignment is required.

 

NOTE: When the invisible beam path is obstructed or

Loosen the sending eye wing nut and readjust, aiming

misaligned while the door is closing, the door will reverse.

 

directly at the receiving eye. Lock in place.

 

If the door is already open, it will not close. The opener

Loosen the receiving eye wing nut and adjust sensor

lights will blink 10 times. See page 16.

 

until it receives the sender’s beam. When the green

 

 

 

indicator light glows steadily, tighten the wing nut.

 

 

Figure 6

 

Connect Wire to

 

 

Opener Quick-Connect Terminals

 

 

Bell Wire

Finished

 

 

 

Ceiling

 

 

 

 

 

1.

Strip wire 7/16"

 

 

Bell Wire

(11 mm) 7/16"

 

 

 

 

(11 mm)

 

 

 

2.

Twist like colored

 

 

 

 

wires together

 

 

 

3. To release or insert

 

 

 

 

wire, push in tab with

 

 

 

 

screwdriver tip

Red White Grey

Safety Reversing Sensor

Quick-Connect Terminals

Invisible Light Beam

Protection Area

Safety Reversing Sensor

18