PROGRAMMING
NOTICE: If this Security✚® door operator is operated with a
To Add or Program a Hand-held Remote Control (Not Provided)
Below are instructions for programming your operator to operate with optional Security✚® remote controls. A maximum of eight Security✚® remote controls can be programmed to work with your operator.
USING THE “LEARN” BUTTON
1. Press and release the purple “learn” button on the motor unit. The learn indicator light will glow steadily for 30 seconds.
2. Within 30 seconds, press and hold the button on the
3. Release the button when the learn indicator light blinks and shuts off upon learning the remote control. If the optional remote light is installed, the light will blink.
4. If the safety reversing sensors are not installed or |
misaligned, the door will not close from a |
control. If this occurs, the door can be closed by pressing |
To Erase All Codes From
Motor Unit Memory
To deactivate any unwanted remote, first erase all codes:
Press and hold the “learn” button on motor unit until the learn indicator light goes out (approximately
*3-Button Remote
If provided with your door operator, the large button is factory programmed to operate it. Additional buttons on any Security✚®
remote can be programmed to operate other Security✚® door
operators.
THE REMOTE CONTROL BATTERY
To prevent possible SERIOUS INJURY or DEATH:
•NEVER allow small children near batteries.
•If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn:
•Replace ONLY with 3V2032 coin batteries.
•Do NOT recharge, disassemble, heat above 100°C (212°F) or incinerate.
and holding the push button on the Single Button Control |
Station until the door has closed. Releasing the push button |
prior to the door closing will cause the door to reverse. |
The lithium battery should produce power for up to 5 years.
To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive side up (+).
Dispose of old battery properly.
Battery positive side up (+)
Replace the battery with only 3V2032 coin cell batteries.
NOTICE: To comply with FCC and or Industry Canada rules (IC), adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
26