MOUNTING AND WIRING THE SAFETY REVERSING SENSORS

Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension. See Figure 5.

Finger tighten the wing nuts.

Figure 5

Wing Nut 1/4"-20

Carriage Bolt

1/4"-20x1/2"

Lens

Recommended Wire Routing

1.Using insulated staples, run the wires from both sensors to the rail at the door header

(see Figure 6).

2.Cross and twist the two wires where they meet the rail (see Figure 6, Illustration A). Run the wires inside the channels at the top of the rail, along each side, to the motor unit. Do not use the lower (trolley) channels. Use a screwdriver tip to tuck the wires snugly into the channels.

HARDWARE SHOWN ACTUAL SIZE

Carriage Bolt

Wing Nut

Staples

1/4"-20x1/2"

1/4"-20

 

NOTE: If your access door is near the garage door, you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires. Use one rail channel for the door control wire and the other channel for both sensor wires. If you choose this option, follow instructions 1-3 on page 20 now.

3.Pull wires taut across the top of the chassis and insert into the opening above the terminal block (see Figure 6, Illustration B). You will complete the wiring in Installation Step 7.

A

Sensor Wire

Header Wall

Figure 6

1.Run wires from sensors to end of rail at the door header. Cross & twist here to help contain wires in channels on top of rail.

2. Run wires along channels

B to motor unit. Use screwdrive blade to tuck snugly into channels.

3. Pull wires taut across top of chassis and insert into opening above terminal block.

Twist

Sensor

Wires

Wire

Header

Bracket

Rail

Channel

Bell Wire

Safety Reversing

 

 

Sensor

Invisible Light Beam

 

 

Protection Area

Safety Reversing Sensor

17