INSTALLATION STEP 7
Install the Door Control
Locate door control within sight of door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of door and door hardware. The installation surface must be smooth and flat. If installing into drywall (Figure 1), drill 5/32" holes and use anchors provided. For
1.Strip 7/16" (11 mm) of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color: white wire to WHT and white/red wire to the RED (Figure 3).
2.Remove cover by gently prying on a side corner near the top of the cover with a small flat head screwdriver (Figure 4). Fasten with
•Drill and install bottom screw, allowing 1/8" (3 mm) to protrude above wall surface.
•Position bottom of door control on screw head and slide down to secure. Adjust screw for snug fit.
•Install top screw with care to avoid cracking plastic housing. Do not overtighten.
•Insert bottom tabs and snap on cover.
NOTE: The push bar may stick if the door control is not mounted on a smooth surface. If a click is not heard when pressing the push bar, loosen the two mounting screws or relocate the door control to a smoother surface.
3. (Standard installation only) Run bell wire up wall |
and across ceiling to motor unit. Use insulated |
staples to secure wire in several places. Do not |
pierce wire with a staple, creating a short or open |
circuit. If your access door is near the garage door, |
you may run this wire with the Safety Reversing |
Sensor wires along the top of the rail. See page 17. |
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution:
•Be sure power is not connected BEFORE installing door control.
•Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing garage door:
•Install door control within sight of garage door, out of reach of children at a minimum height of 5 feet
(1.52 m), and away from all moving parts of door.
•NEVER permit children to operate or play with door control push buttons or remote control transmitters.
•Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel.
•ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door.
HARDWARE SHOWN ACTUAL SIZE
| Screw |
| Insulated |
| Control Panel (std installation) | Staples | |
| Screw |
| Drywall Anchors |
| Control Panel | ||
Figure 1 | STANDARD | Figure 2 | |
INSTALLATION | INSTALLATION |
LOCK |
|
| |
LIGHT | LOCK |
| |
To Replace | LIGHT |
| |
| 24 Volt | ||
Insert Bottom Tabs First | To Replace | ||
Bell Wire | |||
| Insert Bottom Tabs First | ||
|
| ||
Figure 3 | Figure 4 |
|
4. Insert all wires through the opening on top of motor |
unit above the terminal block on the back panel |
(Figure 4). |
5. Strip 7/16" (11 mm) of insulation from each set of bell |
wires. Connect bell wires to the |
terminals as follows: white to white and white/red to |
red; white to white and white/black to grey (Figure 5). |
NOTE: When connecting multiple door controls to the |
opener, twist same color wires together. Insert wires |
into |
to red. |
WALL CONTROL PANEL
Terminal
Screws
Bell
Wire
RED WHT
1 | 2 |
Bottom
Mounting Hole
To release wire, push in tab with screwdriver tip
To
To Sensors
Door
Control
Quick-
Connect
Terminal
6. Use tacks or staples to permanently attach |
entrapment warning label to wall near door control, |
and manual release/safety reverse test label in a |
prominent location on inside of garage door. |
NOTE: DO NOT connect the power and operate the opener at this time. The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned.
Door Control | Safety Sensor |
Connections | Connections |
Red White Grey
7/16" (11 mm)
Strip wire 7/16" (11 mm)
20