PART 2

MASTER/SLAVE LAYOUTS AND WIRING

A.PHOTO-SENSOR INSTALLATION FOR BIPARTING GATE CONFIGURATION BIPARTING SLIDE GATES

Figure 6. Biparting Slide Gate Photo-Sensor Layout.

WARNING

Buy only UL-approved photo-sensors made for use with vehicular gate operators or system. Otherwise, safe gate operation may be compromised.

IMPORTANT NOTE: The installation shown in Figure 6 above is a suggested layout using emitters and receivers. Any UL-approved photo-sensors are acceptable, but they must cover the entire area of gate travel to be effective.

Install photo-sensors in three Coverage Areas as shown in Figure 6.

1.Coverage Area A - Inside-Open Coverage:

Install two photo-sensors: Inside the fence line, from the gate operators to the gate fully open positions.

2.Coverage Area B - Inside-Closed Coverage:

Install one photo-sensor: Inside the fince line, from the Master gate operator to the Slave gate operator.

3.Coverage Area C - Outside-Closed Coverage:

Install one photo-sensor: Outside the fence line, from one fence edge to the other.

4.Connect the photo-sensors to whichever unit is most convenient. For wiring instructions, see Section C, Connecting Input Wiring, below.

Rev E

Doc 01-20201

10 of 33