P O W E R W I R I N G & G R O U N D W I R I N G
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
•ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and
•Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with local electrical codes. The operator should be on a separate fused line of adequate capacity.
•ALL electrical connections MUST be made by a qualified individual.
•DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that you install an optional reversing edge BEFORE proceeding with the control station installation.
•ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled.
•ALL power and control wiring MUST be run in separate conduit.
POWER WIRING CONNECTIONS
1. | Connect power wires coming from the main to the captive |
| terminal block in the electrical box enclosure marked with the |
| label. All power and control wiring must be run in separate |
| conduit in accordance with local electrical codes. |
2. | Be sure to run all power wires through the conduit hole in the |
Single Phase Power Wiring
electrical box enclosure marked with the label shown below. |
Line Power
Hot
NOTE: Must use #14 AWG or thicker wire for power wiring.
ON THREE PHASE MACHINES ONLY: Incorrect phasing of the power supply will cause the motor to rotate in the wrong direction. To change motor rotation, exchange incoming power leads L1 and L2.
GROUND WIRING CONNECTIONS
1.Connect earth ground to the chassis ground screw in the electrical box enclosure.
2.Use same conduit entry into the electrical box as the power wiring.
IMPORTANT NOTE: This unit must be properly grounded. Failure to properly ground this unit could result in electric shock and serious injury.
115/230 Vac Neutral
Single Phase
Gnd
Three Phase Power Wiring
| Phase 1 | |
Line Power | Phase 2 | |
| ||
208/230/380/460/575 Vac | Phase 3 | |
Three Phase | ||
| ||
| Gnd |
10