P R O G R A M M I N G

Built in 3-channel, 315MHz radio receiver allows you to add as many as 23 Security® remotes or dip switch remote controls.

PROGRAMMING REMOTES

STANDARD SINGLE BUTTON REMOTE

1.To enter programming press and release the RADIO button on the logic board (LED will light).

2.Press and hold the remote button until the LED flashes rapidly, then release remote button. The LED will then remain on solid after releasing the button. Repeat to add additional remote(s).

3.Press and release the RADIO button to complete the programming. The programming mode is exited if no activity is performed within 30 seconds.

NOTE: Single button remote is not supported with D1 and E2 failsafe wiring modes.

NOTE: Requires self-monitoring photo eyes when using constant pressure to close (wiring C2, D1 and E2 ).

WARNING

To prevent possible SERIOUS INJURY or DEATH, install reversing sensors when the 3-button control station is out of sight of the door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations.

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.

Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

SINGLE BUTTON CONTROL (SBC) REMOTE

This function programs a remote as a wireless single button control. In B2 mode, operation is OPEN / STOP / CLOSE / REVERSE / STOP. In C2 mode, operation is OPEN / STOP/ Constant pressure to CLOSE / STOP on release. There is no operation in D1 mode. In T and TS modes, operation is OPEN / STOP / CLOSE / REVERSE / STOP and Timer to Close start/refresh. In FSTS mode, operation is OPEN with Timer to Close start/refresh only bypassing all up mid stops. Momentary and constant pressure commands are processed in this function.

 

 

 

OPERATION

 

 

 

 

 

 

 

 

 

MODE

OPEN

STOP

CLOSE

Reverse

Constant

Timer To

Pressure

Close

 

 

 

 

 

B2









 

 

C2





 

 



 

D1

 

 

 

 

 

 

E2





 

 



 

T, TS









 



FSTS



 

 

 

 



 

 

 

 

 

 

 

1.Press and release the RADIO button on the logic board (LED will light).

2.Press and release the SBC externally wired button or TIMER on the logic board (LED flashes rapidly and then remains on solid).

3.Press and hold the remote button until the LED flashes rapidly. The LED will then remain on solid after releasing.

4.Press and release the RADIO button on the logic board (LED flashes rapidly and then turns off). The programming mode is exited if no activity is performed within 30 seconds.

ERASING REMOTES

Press and hold the RADIO button on the logic board until the RADIO LED flashes rapidly (approximately 5 seconds).

All remotes will be erased.

RADIO

LiftMaste r

ÿ14LGÿ65

P4

E1

R29

C11

D3ÿ2

X1

K3

U1

 

 

 

 

 

OLS

D25

 

 

 

 

MID

REV

 

 

 

 

D24

 

 

 

 

SLS

D26

 

 

 

D16

 

 

 

 

 

 

CLS

D27

 

P7

 

 

MRT

MID TI

 

 

 

 

 

 

 

RADIO

1

2

 

 

 

 

D36

 

 

 

 

 

RELAY

 

 

 

C77

 

RELAY

 

 

 

 

 

 

 

 

 

 

D35

 

 

 

C73

 

E2

 

 

 

 

C54

 

 

 

 

D1

 

 

 

 

 

 

 

 

L1

 

 

Æ

C78

 

 

 

C2

C71

L5

 

B2

 

 

 

 

FAILSAFE

 

 

 

 

 

 

 

 

P6

 

 

18