Troubleshooting (continued)

Problem

Possible Cause

Prevention/Solution

 

 

 

Burner will not light

• Rotary knob rotates without clicking.

• Replace knob.

using ignitor.

• Sparking between ignitor and electrode.

• Inspect wire insulation and proper connection. Replace wire if

 

 

 

insulation is broken.

 

 

 

 

• See “GAS ISSUES:” on previous page.

 

Burner will not match

• Match will not reach.

• Use long-stem match (fireplace match).

light.

• Improper method of match-lighting.

• See “Match-Lighting” section of Use and Care.

 

 

 

 

Sudden drop in gas

• Out of gas.

• Check for gas in LP cylinder.

flow or low flame.

• Excess flow valve on regulator tripped.

• Turn off control knob, wait 30 seconds and light appliance. If flames

 

 

 

are still low, turn off knob and LP cylinder valve. Disconnect

 

 

regulator. Reconnect regulator and leak-test. Turn on LP cylinder

 

 

valve, wait 30 seconds and then light appliance.

 

• Vapor lock at coupling nut/LP cylinder

• Turn off knob and LP cylinder valve. Disconnect coupling nut from

 

connection.

cylinder. Reconnect and retry.

 

 

 

Flames blow out.

• Low on LP gas.

• Refill LP cylinder.

 

• Excess flow valve tripped.

• Refer to “Sudden drop in gas flow” above.

 

 

 

Flare-up.

• Grease buildup.

• Clean burner and inside of fryer body.

 

• Excessive fat in meat.

• Trim fat from meat before grilling.

 

• Excessive cooking temperature.

• Adjust (lower) temperature accordingly.

 

 

 

Persistent grease fire.

• Grease trapped by food buildup around

• Turn knob to OFF. Turn gas off at LP cylinder. Let fire burn out. After

 

burner system.

fryer cools, remove and clean all parts.

 

 

 

Flashback...

• Burner is blocked.

• Turn knob to OFF. Clean burner. See burner cleaning section of Use

(fire in burner ).

 

and Care.

 

 

 

Unable to fill LP

• Some dealers have older fill nozzles

• The worn nozzles don’t have enough “bite” to engage the valve. Try

cylinder.

with worn threads.

a second LP dealer.

 

 

 

Cooking slower than

• Vapor Lock

• Turn off control knob and disconnect coupling nut from LP cylinder.

Reconnect and retry.

expected

• Valve not properly aligned to burner

• Loosen control panel and valve. Be sure valve is centered top to

 

 

• High wind conditions

bottom and left to right in burner . Tighten all components once

 

proper alignment is achieved.

 

 

• Relocate the appliance to a less windy area. Use Top Cover during

 

 

cooking.

 

 

 

19

Page 19
Image 19
Char-Broil 10101480 manual Problem Possible Cause Prevention/Solution