3

-Remove two screws that secure each Electrode to Tube Burner (Electrode remains in Firebox).

-Lift back end of burner while sliding Tube Burner out of Firebox, disengaging burners from Valves.

Screws

Tube

Burner

Electrode

Firebox ofGrill Front

Valve

Tube

Burner

 

Tube

Burner

 

4

-Insert Orifice Removal Tool provided with Kit into Firebox Burner openings and unscrew Orifices from ends of Valves. Save removed Orifices for converting back to LP Tank Gas. These grill valves are designed to work with Natural Gas once Orifices are removed. Do not replace any Orifices when using Natural Gas. Note: This gas conversion kit comes with replacement Orifices for the Rotisserie Burner ONLY, if applicable, do not use on Tube Burner valves. See later steps for Rotisserie conversion.

Valve

Orifice

Grill

Firebox

 

of

 

Front

 

Burner Opening

Orifice Removal Tool

6 • Natural Gas Conversion Kit

Page 6
Image 6
Char-Broil 4984619 manual Screws Tube Burner Electrode, Valve Tube, Valve Orifice, Burner Opening Orifice Removal Tool