Chapter 1. IBM PC Enhanced Diagnostics error codes

Refer to the following Diagnostic Error Codes when using the IBM PC Enhanced Diagnostics test. See the Diagnostic and test informationsection for the specific model for information about the IBM PC Enhanced Diagnostics program.

In the following index, X can represent any number.

Diagnostic Error Code

FRU/Action

 

 

 

000-000-XXXBIOS Test Passed

1.

No action

 

 

 

 

000-002-XXXBIOS Timeout

1.

Flash the system

 

 

2.

System board

 

 

 

000-024-XXXBIOS Addressing test failure

1.

Flash the system

 

 

2.

System board

 

 

 

000-025-XXXBIOS Checksum Value error

1.

Flash the system

 

 

2.

Boot block

 

3.

System board

 

 

 

000-026-XXXFLASH data error

1.

Flash the system

 

 

2.

Boot block

 

3.

System board

 

 

 

000-027-XXXBIOS Configuration/Setup error

1.

Run Setup

 

 

2.

Flash the system

 

3.

Boot block

 

4.

System board

 

 

 

000-034-XXXBIOS Buffer Allocation failure

1.

Reboot the system

 

 

2.

Flash the system

 

3.

Run memory test

 

4.

System board

 

 

 

000-035-XXXBIOS Reset Condition detected

1.

Flash the system

 

 

2.

System board

 

 

 

000-036-XXXBIOS Register error

1.

Flash the system

 

 

2.

Boot block

 

3.

System board

 

 

 