IBM 6649, 6578, 6579, 6269, 6059, 6058, 6569, 6568, 6648 Adapter card, Power-off/on system and re-test

Models: 6568 6649 6058 6269 6569 6578 6059 6579 6648

1 248
Download 248 pages 20.59 Kb
Page 17
Image 17

Diagnostic Error Code

FRU/Action

 

 

 

001-027-XXXSystem Configuration/Setup error

1.

Run Setup

 

2.

Flash the system

 

3.

System board

 

 

 

001-032-XXXSystem Device Controller failure

1.

System board

 

 

 

 

001-034-XXXSystem Device Buffer Allocation

1.

Reboot the system

failure

2.

Flash the system

 

 

3.

Run memory test

 

4.

System board

 

 

 

001-035-XXXSystem Device Reset condition

1.

System board

detected

 

 

 

 

 

001-036-XXXSystem Register error

1.

System board

 

 

 

 

001-038-XXXSystem Extension failure

1.

Adapter card

 

 

2.

System board

 

 

 

001-039-XXXSystem DMI data structure error

1.

Flash the system

 

 

2.

System board

 

 

 

001-040-XXXSystem IRQ failure

1.

Power-off/on system and re-test

 

 

2.

System board

 

 

 

001-041-XXXSystem DMA failure

1.

Power-off/on system and re-test

 

 

2.

System board

 

 

 

001-195-XXXSystem Test aborted by user

1.

Information

 

 

2.

Re-start the test, if necessary

 

 

 

001-196-XXXSystem test halt, error threshold

1.

Press F3 to review the log file

exceeded

2.

Re-start the test to reset the log file

 

 

 

 

001-197-XXXSystem test warning

1.

Make sure the component that is called out is

 

 

 

connected and/or enabled

 

2.

Re-run test

 

3.

Component that is called out in warning statement

 

4.

Component under test

 

 

 

001-198-XXXSystem test aborted

1.

If a component is called out, make sure it is

 

 

 

connected and/or enabled

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problemssection

 

 

 

Chapter 1. IBM PC Enhanced Diagnostics error codes 3

Page 17
Image 17
IBM 6649, 6578, 6579, 6269, 6059, 6058, 6569, 6568, 6648 manual Adapter card, Power-off/on system and re-test