Diagnostic Error Code FRU/Action
170-197-XXXVoltageSensor(s) test warning 1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
170-198-XXXVoltageSensor(s) test aborted 1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problemssection
170-199-XXXVoltageSensor(s) test failed, cause
unknown 1. Go to the Undetermined problemssection
2. Flash the system and re-test
3. Replace component under function test
170-250-XXX
170-251-XXXVoltageSensor(s) Voltage limit
error
1. Power supply
2. System board
170-254-XXXVoltageSensor(s) Voltage
Regulator Module error 1. VoltageRegulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXXThermal Sensor(s) TestPassed 1. No action
175-0XX-XXXThermal Sensor(s) failure 1. Flash system
2. System board
175-195-XXXThermal Sensor(s) Testaborted by
user 1. Information
2. Re-start the test, if necessary
175-196-XXXThermal Sensor(s) test halt, error
threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXXThermal Sensor(s) test warning 1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
175-198-XXXThermal Sensor(s) test aborted 1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to Undetermined problemssection
18 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,