IBM 6568 XXX Check fans, Assure Asset Security Enabled, Replace the memory module called out by

Models: 6568 6649 6058 6269 6569 6578 6059 6579 6648

1 248
Download 248 pages 20.59 Kb
Page 33
Image 33

Diagnostic Error Code

FRU/Action

 

 

 

175-199-XXXThermal Sensor(s) test failed,

1.

Go to the Undetermined problemssection

cause unknown

2.

Flash the system and re-test

 

 

3.

Replace component under function test

 

 

 

175-250-XXX

1.

Check fans

175-251-XXXThermal Sensor(s) limit error

2.

Check Power supply

 

 

3.

Microprocessor

 

4.

System board

 

 

 

185-000-XXXAsset Security Test Passed

1.

No action

 

 

 

 

185-XXX-XXXAsset Security failure

1.

Flash system

 

 

2.

System board

 

 

 

185-278-XXXAsset Security Chassis Intrusion

1.

Assure Asset Security Enabled

 

 

2.

C2 Cover Switch

 

3.

System board

 

 

 

201-000-XXXSystem Memory Test Passed

1.

No action

 

 

 

 

201-XXX-XXXSystem Memory error

1.

Replace the memory module called out by the

 

 

 

test

 

2.

System board

 

 

 

202-000-XXXSystem Cache Test Passed

1.

No action

 

 

 

 

202-XXX-XXXSystem Cache error

1.

Cache, if removable

 

 

2.

System board

 

3.

Microprocessor

 

 

 

206-000-XXXDiskette Drive Test Passed

1.

No action

 

 

 

 

206-XXX-XXXDiskette Drive error

1.

Diskette Drive Cable

 

 

2.

Check power supply voltages

 

3.

Diskette drive

 

4.

System board

 

 

 

215-000-XXXCD-ROM Drive Test Passed

1.

No action

 

 

 

 

215-XXX-XXXCD-ROM Drive error

1.

CD-ROM Drive Cable

 

 

2.

Check power supply voltages

 

3.

CD-ROM drive

 

4.

System board

 

 

 

217-000-XXXHard Disk Drive Test Passed

1.

No action

 

 

 

 

Chapter 1. IBM PC Enhanced Diagnostics error codes 19

Page 33
Image 33
IBM 6568 XXX Check fans, Assure Asset Security Enabled, Replace the memory module called out by, Test, Cache, if removable