IBM 6649, 6578, 6579, 6269, 6059, 6058, 6569, 6568, 6648 manual 5XX

Models: 6568 6649 6058 6269 6569 6578 6059 6579 6648

1 248
Download 248 pages 20.59 Kb
Page 89
Image 89

POST Error Code

FRU/Action

 

 

 

189

1.

More than three password attempts were

 

 

 

made to access the computer

 

 

 

190Chassis intrusion detector was cleared. This is

1.

System Board

information only, no action required. If this code

 

 

does not clear:

 

 

 

 

 

1XXNot listed above

1.

System Board

 

 

 

 

201, 20XMemory data error

1.

Run Enhanced Diagnostics Memory Test

 

 

2.

Memory Module

 

3.

System Board

 

 

 

225

1.

Unsupported Memory

 

 

 

 

229External cache test error

1.

L2 Cache Memory

 

 

2.

System Board

 

 

 

262POST detected a base memory or extended

1.

Run Setup. Check System Summary menu for

memory type error

 

memory. (See “Setup Utility program” on

 

 

 

 

page 41.)

 

2.

Run the Extended Memory Diagnostic tests.

 

 

 

301

1.

Keyboard

 

 

2.

Keyboard Cable

 

3.

System Board

 

 

 

303With an 8603 error

1.

Mouse

 

 

2.

Keyboard

 

3.

Keyboard Cable

 

4.

System Board

 

 

 

303With no 8603 error

1.

Keyboard

 

 

2.

Keyboard Cable

 

3.

System Board

 

 

 

3XXNot listed above

1.

Keyboard

 

 

2.

Keyboard Cable

 

3.

System Board

 

 

 

5XX

1.

Video Adapter (if installed)

 

 

2.

System Board

 

 

 

601

1.

Diskette Drive A

 

 

2.

Diskette Drive Cable

 

3.

System Board

 

4.

Riser card

 

 

 

Chapter 2. Types 6568/6569/6648/6649 75

Page 89
Image 89
IBM 6649, 6578, 6579, 6269, 6059, 6058, 6569, 6568, 6648 manual 5XX