Message/Symptom

FRU/Action

 

 

 

Non-system disk or disk error-type message with

1.

Diskette Drive

a known-good diagnostic diskette.

2.

System Board

 

 

3.

Diskette Drive Cable

 

4.

Riser card

 

 

 

Drives not recognized by the Fixed Disk diagnostic

1.

Remove the first drive that does not show up

(e.g., you have six drives but the fixed disk test

 

and rerun the Fixed Disk diagnostic. If the

only shows three)

 

 

remaining drives then show up, replace the

 

 

 

 

drive you removed.

 

 

 

Hang during Fixed Disk diagnostic

1.

Remove the hard file being tested at the time

 

 

 

of the hang.

 

2.

Rerun the diagnostic.

 

3.

If successful, replace the drive you removed.

 

 

 

Other display symptoms not listed above

1.

See “Display” on page 32

(including blank or illegible display)

2.

System Board

 

 

3.

Display

 

 

 

Power-on indicator or hard disk drive in-use light

1.

Power Supply

not on, but computer works correctly

2.

System Board

 

 

3.

LED Cables

 

 

 

Printer problems

1.

See “Printer” on page 29

 

 

 

 

Program loads from the hard disk with a

1.

Run Setup

known-good diagnostics diskette in the first

2.

Diskette Drive

3.5-inch diskette drive

3.

Diskette Drive Cable

 

 

4.

System Board

 

5.

Riser card

 

6.

Power Supply

 

 

 

RPL computer cannot access programs from its

1.

If network administrator is using LCCM

own hard disk.

 

Hybrid RPL, check startup sequence:

 

 

 

 

a. First device - network

 

 

b. Second device - hard disk

 

2.

Hard disk drive

 

 

 

RPL computer does not RPL from server

1.

Check startup sequence

 

 

2.

Check the network adapter LED status

 

 

 

Chapter 2. Types 6568/6569/6648/6649 89

Page 103
Image 103