Message/Symptom

FRU/Action

 

 

 

Power-on indicator or hard disk drive in-use light

1.

Power Supply

not on, but computer works correctly

2.

System Board

 

 

3.

LED Cables

 

 

 

Printer problems

1.

See “Printer” on page 107

 

 

 

 

Program loads from the hard disk with a

1.

Run Setup

known-good diagnostics diskette in the first

2.

Diskette Drive

3.5-inch diskette drive

3.

Diskette Drive Cable

 

 

4.

System Board

 

5.

Power Supply

 

 

 

Drives not recognized by the Fixed Disk diagnostic

1.

Remove the first drive that does not show up

(e.g., you have six drives but the fixed disk test

 

and rerun the Fixed Disk diagnostic. If the

only shows three)

 

 

remaining drives then show up, replace the

 

 

 

 

drive you removed.

 

 

 

Hang during Fixed Disk diagnostic

1.

Remove the hard file being tested at the time

 

 

 

of the hang.

 

2.

Rerun the diagnostic.

 

3.

If successful, replace the drive you removed.

 

 

 

RPL computer cannot access programs from its

1.

If network administrator is using LCCM

own hard disk.

 

Hybrid RPL, check startup sequence:

 

 

 

 

a. First device - network

 

 

b. Second device - hard disk

 

2.

Hard disk drive

 

 

 

RPL computer does not RPL from server

1.

Check startup sequence

 

 

2.

Check the network adapter LED status

 

 

 

Serial or parallel port device failure (system board

1.

External Device Self-Test OK?

port)

2.

External Device

 

 

3.

Cable

 

4.

System Board

 

 

 

Serial or parallel port device failure (adapter port)

1.

External Device Self-Test OK?

 

 

2.

External Device

 

3.

Cable

 

4.

Alternate Adapter

 

5.

System Board

 

 

 

Chapter 3. Types 6058/6059/6269/6578/6579 169

Page 183
Image 183
IBM 6059, 6578, 6579, 6269, 6058, 6569, 6568, 6648, 6649 manual See Printer on