IBM 6649, 6578, 6579, 6269, 6059, 6058, 6569 XXX PCI card, XXX No action, 025-00X-XXX IDE signal cable

Models: 6568 6649 6058 6269 6569 6578 6059 6579 6648

1 248
Download 248 pages 20.59 Kb
Page 26
Image 26

Diagnostic Error Code

FRU/Action

 

 

 

020-197-XXXPCI test warning

1.

Make sure the component that is called out is

 

 

 

connected and/or enabled

 

2.

Re-run test

 

3.

Component that is called out in warning statement

 

4.

Component under test

 

 

 

020-198-XXXPCI test aborted

1.

If a component is called out, make sure it is

 

 

 

connected and/or enabled

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problemssection

 

 

 

020-199-XXXPCI test failed, cause unknown

1.

Go to the Undetermined problemssection

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

020-262-XXX

1.

PCI card

PCI system error

2.

Riser card, if installed

 

 

3.

System board

 

 

 

025-000-XXX

1.

No action

IDE interface Test Passed

 

 

 

 

 

025-00X-XXX

1.

IDE signal cable

025-01X-XXXIDE interface failure

2.

Check power supply

 

 

3.

IDE device

 

4.

System board

 

 

 

025-027-XXXIDE interface Configuration/Setup

1.

IDE signal cable

error

2.

Flash the system

 

 

3.

IDE device

 

4.

System board

 

 

 

025-02X-XXX

1.

IDE signal cable

025-03X-XXX

2.

Check power supply

025-04X-XXXIDE Interface failure

3.

IDE device

 

 

4.

System board

 

 

 

025-195-XXXIDE interface Test aborted by user

1.

Information

 

 

2.

Re-start the test, if necessary

 

 

 

025-196-XXXIDE interface test halt, error

1.

Press F3 to review the log file

threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

12Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Page 26
Image 26
IBM 6649, 6578, 6579 XXX PCI card, XXX No action, 025-00X-XXX IDE signal cable, 025-02X-XXX IDE signal cable 025-03X-XXX