Diagnostic Error Code

FRU/Action

 

 

 

005-024-XXXVideo Addressing test failure

1.

Video card, if installed

 

 

2.

System board

 

 

 

005-025-XXXVideo Checksum Value error

1.

Video card, if installed

 

 

2.

System board

 

 

 

005-027-XXXVideo Configuration/Setup error

1.

Run Setup

 

 

2.

Video drivers update

 

3.

Video card, if installed

 

4.

System board

 

 

 

005-031-XXXVideo Device Cable failure

1.

Video cable

 

 

2.

Monitor

 

3.

Video card, if installed

 

4.

System board

 

 

 

005-032-XXXVideo Device Controller failure

1.

Video card, if installed

 

 

2.

System board

 

 

 

005-036-XXXVideo Register error

1.

Video card, if installed

 

 

2.

System board

 

 

 

005-038-XXXSystem BIOS extension failure

1.

Video card, if installed

 

 

2.

System board

 

 

 

005-040-XXXVideo IRQ failure

1.

Video card, if installed

 

 

2.

System board

 

 

 

005-195-XXXVideo Test aborted by user

1.

Information

 

 

2.

Re-start the test, if necessary

 

 

 

005-196-XXXVideo test halt, error threshold

1.

Press F3 to review the log file

exceeded

2.

Re-start the test to reset the log file

 

 

 

 

005-197-XXXVideo test warning

1.

Make sure the component that is called out is

 

 

 

connected and/or enabled

 

2.

Re-run test

 

3.

Component that is called out in warning statement

 

4.

Component under test

 

 

 

005-198-XXXVideo test aborted

1.

If a component is called out, make sure it is

 

 

 

connected and/or enabled

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problemssection

 

 

 

6Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Page 20
Image 20
IBM 6269, 6578, 6579, 6059, 6058, 6569, 6568, 6648, 6649 manual Run Setup, Video cable