IBM 6649, 6569, 6568, 6648 manual Specifications Types 6058/60596269/6578/6579, 705 BTU/hr watts

Models: 6568 6649 6058 6269 6569 6578 6059 6579 6648

1 248
Download 248 pages 20.59 Kb
Page 116
Image 116

Specifications Information (ISO/ANSI)

The machine type specifications information on the following pages was determined in controlled acoustical environments according to procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779, and are reported in accordance with ISO 9296. Actual sound pressure levels in your location might differ from the average values stated because of room reflections and other nearby noise sources. The declared sound power levels indicate an upper limit, below which a large proportion of machines will operate.

Specifications -

Types 6058/60596269/6578/6579

Feature

Description

 

 

Size

Depth: 425 mm (16.7 inches)

 

Height: 140 mm (5.5 inches)

 

Width: 425 mm (16.7 inches)

 

 

Weight

Minimum configuration as shipped:

 

9.4 kg (20 lb)

 

Maximum configuration as shipped: 11.3 kg (25 lb)

 

 

Environment

Air temperature:

 

v System on: 10 to 35 C

 

 

(50 to 95 F)

 

v System off: 10 to 43 C

 

 

(50 to 110 F)

 

Humidity:

 

v

System on: 8% to 80%

 

v

System off: 8% to 80%

 

Maximum altitude: 2134 m (7000 ft.)

 

 

Heat Output

Approximate heat output in BTUs per hour:

 

v

Minimum:

 

 

240 BTU/hr. (75 watts)

 

v

Maximum:

 

 

705 BTU/hr. (207 watts)

 

 

 

102Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,